CTHIn ForceLegislation
Greenhouse and Energy Minimum Standards (LED Lamps) Determination 2025
26Lamp ageing and lamp operating orientation
Start here
Get a plain-English read of 26
Turn the raw legal text into a practical explanation grounded in Greenhouse and Energy Minimum Standards (LED Lamps) Determination 2025.
26 Lamp ageing and lamp operating orientation
The lamp ageing and lamp operating orientation requirements for conducting testing in accordance with section 22 on LED lamps in product classes covered by this instrument are as follows:
<table cellspacing="0" cellpadding="0" style="width:408pt; margin-left:5.65pt; border-collapse:collapse"><tbody><tr style="height:13.75pt"><td colspan="4" style="width:396.9pt; border-top:1.5pt solid #000000; border-bottom:0.75pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="TableHeading"><span>Table: Requirements for lamp test conditions</span></p></td></tr><tr style="height:25.3pt"><td style="width:25.65pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="TableHeading"><span>Item</span></p></td><td style="width:95.95pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="TableHeading"><span>Column 1</span></p><p class="TableHeading"><span>Lamp test conditions</span></p></td><td style="width:138.05pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="TableHeading"><span>Column 2</span></p><p class="TableHeading"><span>AS/NZS 5341 default conditions</span></p></td><td style="width:104.85pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="TableHeading"><span>Column 3</span></p><p class="TableHeading"><span>Guidance notes</span></p></td></tr><tr style="height:119pt"><td style="width:25.65pt; border-top:1.5pt solid #000000; border-bottom:0.75pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>1</span></p></td><td style="width:95.95pt; border-top:1.5pt solid #000000; border-bottom:0.75pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>Lamp ageing</span></p></td><td style="width:138.05pt; border-top:1.5pt solid #000000; border-bottom:0.75pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>0 hours</span></p></td><td style="width:104.85pt; border-top:1.5pt solid #000000; border-bottom:0.75pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>The AS/NZS 5341 default requirements apply unless the technical documentation provided at product registration advises otherwise.</span></p><p class="Tabletext"><span></span></p><p class="nm"><span>Note:</span><span style="width:15.45pt; text-indent:0pt; display:inline-block"> </span><span>AS/NZS 5341 allows ageing up to 1,000 hours.</span></p></td></tr><tr style="height:77.75pt"><td style="width:25.65pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>2</span></p></td><td style="width:95.95pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>Lamp operating orientation</span></p></td><td style="width:138.05pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>Single-capped lamp:</span></p><p class="Tabletext" style="margin-left:21.25pt"><span>Vertical base up orientation</span></p><p class="Tabletext"><span>Double-capped lamp:</span></p><p class="Tabletext" style="margin-left:21.25pt"><span>Major lamp axis in horizontal orientation</span></p></td><td style="width:104.85pt; border-top:0.75pt solid #000000; border-bottom:1.5pt solid #000000; padding-right:5.4pt; padding-left:5.4pt; vertical-align:top"><p class="Tabletext"><span>The AS/NZS 5341 default requirements apply unless the technical documentation provided at product registration advises otherwise.</span></p></td></tr></tbody></table> ```