CTHIn ForceLegislation
Future Made in Australia (Guarantee of Origin) Methodology Determination 2025
Part 2Scope 3 emission factor supplements for advanced water treatment processes
Start here
Get a plain-English read of Part 2
Turn the raw legal text into a practical explanation grounded in Future Made in Australia (Guarantee of Origin) Methodology Determination 2025.
Part 2—Scope 3 emission factor supplements for advanced water treatment processes
Note: See paragraph 17(2)(b) and subsection 17(4).
| Column 1 | Column 2 | Column 3 | Column 4 |
|---|---|---|---|
| Item | Advanced treatment process | Water quality post-treatment process | Emission factor in kg of CO2-e per kg of water |
| 1 | Ultrapure membrane process | Water for electrolyser feed-water qualityConductivity less than 0.1 micro-Siemens per centimetre (µS/cm) and total silica less than 0.01 milligrams per litre (mg/L) | 0.001836 |
| 2 | Ultrapure thermal process | Water for electrolyser feed-water qualityConductivity less than 0.1 µS/cm and total silica less than 0.01 mg/L | 0.036991 |
| 3 | Demineralised or deionised via electro-deionisation | Boiler feedwater for steam generation qualityConductivity less than 1 µS/cm, total silica less than 0.02 mg/L and less than 0.08 Total Organic Carbon | 0.001741 |
| 4 | Water softening by ion exchange | Water hardness less than 0.02 mmol/L | 0.000335 |
| 5 | Ultrafiltered membrane process | Particulate matter larger than 0.01 µm removed and turbidity below 0.1 Nephelometric Turbidity Units | 0.004356 |
| 6 | Filtered clarifier | Total suspended solids reduced to below 1 mg/L or turbidity less than 10 Nephelometric Turbidity Units | 0.000509 |