Compliance with AD/F100/84 is a multi‑step process that must be documented and integrated into the operator’s continuing airworthiness management system. The first step is to determine applicability. The operator must identify each F28 Mark 0070 or Mark 0100 it operates with a serial number between 11244 and 11585, and then verify whether those aircraft are fitted with fuel crossfeed valve and fuel fire shut‑off valve actuators bearing P/N 9409122. If only one or neither actuator type has that P/N, the obligations attach only to the affected ones. However the AD uses the phrases “fuel crossfeed valve- and fuel fire shut-off valve actuators” together, suggesting the checks apply to both types. An aircraft with only one actuator of that P/N may still be subject; read carefully.
Second, the operator must obtain the approved revision of Fokker Service Bulletin SBF-100-28-049. As of 2007, the original issue of the bulletin may have been approved. The operator must check with CASA or the CASA AD database to confirm that revision remains current or if a later revision has been approved. The bulletin will contain the detailed procedural steps for the operational check and the grease application method.
Third, the initial compliance must be accomplished within 30 days after 5 July 2007 - that is, by 4 August 2007. The work includes an operational check of each actuator (LH and RH for both crossfeed and fire shut‑off) and application of grease to a layer of approximately 2-3 mm. The operator should document the date of this initial compliance in the aircraft maintenance log.
Fourth, after initial compliance, the operator must establish recurring inspection intervals. A 7‑day visual inspection of the grease layer is required. This inspection does not require an operational check; it is purely visual to confirm the grease layer is still present and sufficient. The operator must schedule this at intervals not exceeding 7 calendar days. It is good practice to set the interval at 7 days with no grace period, but the regulatory requirement is “not to exceed 7 days”, meaning if the inspection is performed on day 7, it complies. However performing it on day 8 would be late. A practical approach is to schedule it every 7 days with a one‑day buffer.
Fifth, a separate operational check and visual inspection must be performed at intervals not exceeding 28 days. This check requires the actual movement of the valve actuator (likely via flight deck controls or test equipment) to confirm the actuator operates freely. Because the operational check also includes a visual inspection, the 28‑day check may be combined with the 7‑day visual inspection if the timing aligns, but the operator must ensure the 7‑day requirement is not exceeded by waiting for the 28‑day check.
Sixth, whenever a visual inspection reveals insufficient grease (less than approx. 2-3 mm), the operator must reapply grease before the next flight. This is a repetitive corrective action. The AD does not give a fixed compliance time; it says “before further flight”. The operator must have grease and the service bulletin available to perform this reapplication immediately.
Seventh, if any actuator fails an operational check (either initial or recurring), the operator must determine whether it is a fire shut‑off valve actuator (requiring replacement before further flight with no alternative) or a crossfeed valve actuator (replacement before further flight or operation under MMEL item 28-23-1). For MMEL operation, the operator must ensure that its MEL has been approved for that item and that the dispatch conditions (likely a limit on the number of days or cycles) are met. The operator must also document the MMEL usage in the technical log.
Eighth, the operator must maintain auditable records: dates of initial compliance, dates of each visual inspection and each operational check, results, any findings of insufficient grease, any grease reapplications, any actuator replacements, and any MMEL usage. These records must be retained for the life of the aircraft under the applicable airworthiness regulations.
Ninth, because the AD does not expire, the operator should consider a terminating action: fitting the redesigned actuator (when available) that eliminates the ice formation issue. Installing the new actuator removes the need for the recurring checks, reducing long‑term maintenance costs and compliance risk. The operator should monitor for availability of a service bulletin that installs the new actuator and for a new AD that would supersede AD/F100/84 or make the recurring actions no longer necessary.
Tenth, if the operator finds compliance with the 7‑day interval impracticable for some operations (e.g., aircraft in storage or infrequent use), it may apply to CASA for an alternative means of compliance or an extension. The AD itself does not provide any relief; any relief must be formally approved by CASA under the regulations. The operator should plan for the recurring interval as a hard requirement.