CTHIn ForceLegislation
AD/CL-600/59 - IDG Cables
Part A.- For CL-600-2B19 "Regional Jet" Aircraft
Start here
Get a plain-English read of Part A.
Turn the raw legal text into a practical explanation grounded in AD/CL-600/59 - IDG Cables.
Part A. - For CL-600-2B19 "Regional Jet" Aircraft
For aircraft S/N 7003 through 7067 and 7069 through 7301, inspect the integrated drive generator (IDG) cables to verify clearances, and repair or replace the IDG cables as required, in accordance with Canadair Alert Service Bulletin (ASB) A601R-24-095 dated 23 March 1999, or ASB A601R-24-095, Revision A, dated 25 March 1999.
For aircraft S/N 7003 through 7067 and 7069 through 7303, inspect, verify and correct (if required) the clearance between the 10th stage bleed air check valve and the fuel manifold pigtails in accordance with Canadair ASB A601R-73-008 dated 1 April 1999, or ASB A601R-73-008, Revision A, dated 10 April 1999. If there is damage to the fuel manifold pigtails, inspect in accordance with General Electric (GE) CF34 Engine Manual SEI-756, Chapter 72-09-05 (Hose and Tube Assemblies - Inspection/Hose and Tube Assemblies - Repair) to determine serviceability; repair if required.
3. Report the findings of the above inspections (and corrective action if required) to Bombardier.