AD/BELL 206/120 - Bogus Pressure Gauge Emergency Floats P/N 212-073-905-1
1AD/BELL 206/120 - Bogus Pressure Gauge Emergency Floats P/N 212-073-905-1
Start here
Get a plain-English read of 1
Turn the raw legal text into a practical explanation grounded in AD/BELL 206/120 - Bogus Pressure Gauge Emergency Floats P/N 212-073-905-1.
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Image unavailable in extracted text Bell Helicopter Textron Canada (BHTC) 206 and Agusta Bell 206 Series Helicopters
AD/BELL 206/120 Bogus Pressure Gauge Emergency
Floats P/N 212-073-905-1
4/90
DM
Applicability: All models.
Requirement: Action in accordance with Bell OSN-GEN-89-14.
Compliance: At the next inspection for Maintenance Release issue after 28 February 1990 or before the next charging of the emergency float reservoir, whichever is earlier.
Background: The aircraft manufacturer has had reported an incident where the subject pressure gauge exploded at only 2000 psig. The gauge was subsequently found to be bogus. Failure of the bogus gauge could severely injure maintenance personnel.