AD/B737/299 - Electrical Bonding
Boeing 737 Series AeroplanesBoeing 737 Series Aeroplanes
Start here
Get a plain-English read of Boeing 737 Series Aeroplanes
Turn the raw legal text into a practical explanation grounded in AD/B737/299 - Electrical Bonding.
Boeing 737 Series Aeroplanes
| AD/B737/299 | Electrical Bonding | 3/2007 |
|---|
| Applicability: | Model 737-600, -700, -700C, -800 and -900 series aeroplanes, as identified in Boeing Special Attention Service Bulletin (SB) 737-28-1225, Revision 1, dated30 October 2006. |
|---|---|
| Requirement: | 1. Test the electrical resistance of the bond between the bulkhead fitting for the fuel feed line and the wing front spar on the left and right wings and carry out a general visual inspection of adjacent bonding jumpers to make sure they are installed correctly. Both actions are to be accomplished in accordance with the SB 737-28-1225, Revision 1. |
| 2. Carry out all applicable corrective actions in accordance with SB 737-28-1225, Revision 1. | |
| Actions accomplished before the effective date of this Directive in accordance with Boeing Special Attention Service Bulletin 737-28-1225 dated 12 January 2006, are considered acceptable for compliance with the actions required by this Directive. | |
| Later revisions of the above SB, approved by the United States Federal Aviation Administration (FAA) as an Alternate Method of Compliance (AMOC) to FAA AD 2007-02-14, are considered acceptable for compliance with the equivalent Requirements of this Directive. | |
| Note: FAA AD 2007-02-14 refers. | |
| Compliance: | For Requirement 1 - Within 60 months after the effective date of this Directive. |
| For Requirement 2 - Before further flight after the Requirement 1 electrical resistance test. | |
| This Airworthiness Directive becomes effective on 15 March 2007. |
| Background: | This Directive requires testing the electrical resistance of the bond between the bulkhead fitting for the fuel feed line and the front spar of the left and right wings, inspecting an adjacent bonding jumper to make sure it is installed correctly and, if necessary, performing corrective and other specified actions as applicable. The Directive is issued to prevent arcing or sparking in the fuel tank in the event of a lightning strike, which could result in an uncontrolled fire or explosion. |
|---|