[2025] VCAT 499
General information, not legal advice.
Victorian Civil and Administrative Tribunal
2025-06-05
Original judgment source is linked above.
SHOULD THE CONDITION RELATING TO RETAINING WALLS BE REVISED?
All retaining structures are to be no greater than 1 metre in height per individual retaining wall and no greater 3m in total, with a minimum of 0.75m distance stagger between each stagger and positioned so that associated drainage infrastructure is retained within each lot, unless otherwise agreed in writing by the Responsible Authority.
Unless otherwise agreed in writing by the Responsible Authority:
a) At the front of lots and in public open space areas, all retaining structures are to be no greater than 1 metre in height per individual retaining wall.
b) At the side and rear of lots, retaining structures are to be no greater than 2.5 metres in height per individual retaining wall.
c) Where retaining of more than 2.5 metres is required, retaining walls must be staggered with a minimum of 0.75 distance between each stagger and positioned so that associated drainage infrastructure is retained within each lot.
Subdivision applications for land of a slope greater than 10-per-cent must be accompanied by the following information, as appropriate:
Any vertical retaining structures in public places (with the exception of those that are part of building walls) must be no more than 1.0 metres in height, unless otherwise agreed by the responsible authority.
Any retaining structures (with the exception of those which are part of building) should be:
SHOULD THE CONDITION RELATING TO EXPIRY BE REVISED?
a) The Plan of Subdivision for the first stage has not been certified under the Subdivision Act 1988 within 3 years of the issued date of this permit.
[1] The General Residential Zone is the applied zone under Schedule 1 to cl 37.07.
[2] The Tribunal's decision considers submissions, evidence, supporting hearing exhibits and the statements of grounds. Not all of this material will be referred to in these reasons.
[3] I considered the relationship between these requirements and guidelines in W295 Pty Ltd atf 295 Unit Trust v Baw Baw SC [2024] VCAT 612 commencing at paragraph 80.
[4] Mr Ravida identified a small number of areas where a retaining wall on a side boundary may be over 1 metre in height within the 1 metre front setback.
[5] In the course of the proceeding W295 Pty Ltd atf 295 Unit Trust v Baw Baw SC [2024] VCAT 612 I viewed an extensive number of new subdivisions in the PSP around Warragul.
Gippsland 7 Pty Ltd
Baw Baw SC [2025] VCAT 499