476 Action if respirable asbestos fibre level too high
(1) The licensed removalist carrying out asbestos removal work
requiring a Class A asbestos removal licence at a workplace must:
(a) if respirable asbestos fibre levels are recorded at the asbestos
removal area at 0.01 fibres/ml or more, but not more than
0.02 fibres/ml – immediately:
(i) investigate the cause of the respirable asbestos fibre
level; and
(ii) implement controls to prevent exposure of anyone to
asbestos; and
(iii) prevent the further release of respirable asbestos fibres;
and
(b) if respirable asbestos fibre levels are recorded at the asbestos
removal area at more than 0.02 fibres/ml – immediately:
(i) order the asbestos removal work to stop; and
(ii) notify the regulator; and
Work Health and Safety (National Uniform Legislation) Regulations 2011 373
(iii) investigate the cause of the respirable asbestos fibre
level; and
(iv) implement controls to prevent exposure of anyone to
asbestos; and
(v) prevent the further release of respirable asbestos fibre.
(2) If the licensed removalist stops asbestos removal work requiring a
Class A asbestos removal licence because the recorded respirable
asbestos fibre level exceeds 0.02 fibres/ml, the removalist must
ensure that the asbestos removal work does not resume until air
monitoring shows that the recorded respirable asbestos fibre level
is below 0.01 fibres/ml.