Victorian Energy Efficiency Target Regulations 2018
18Conditions and circumstances under which a certificate cannot be created for a lighting upgrade under Part 27
Start here
Get a plain-English read of 18
Turn the raw legal text into a practical explanation grounded in Victorian Energy Efficiency Target Regulations 2018.
18 Conditions and circumstances under which a certificate cannot be created for a lighting upgrade under Part 27
A certificate cannot be created in relation to a prescribed activity that is a lighting upgrade referred to in Part 27 of Schedule 2 unless—
(a) a lighting design has been prepared for the lighting upgrade which—
(i) is prepared by a lighting designer who is qualified to undertake the lighting design; and
(ii) sets out the location and specifications of all existing street lights in the area to which the lighting design applies; and
(iii) sets out the location and specifications of all lighting equipment to be installed in the area to which the lighting design applies; and
(iv) includes a declaration by the lighting designer stating that—
(A) the light output of the lighting upgrade specified in the lighting design complies with the relevant part or parts of AS/NZS 1158; or
(B) if the light output of the lighting upgrade specification in the lighting design deviates from AS/NZS 1158, the deviations are justified in accordance with the Standard and setting out the reasons why the deviations are justified; and
(b) the energy consumer has demonstrated acceptance of the lighting design in accordance with the determination of the ESC under regulation 36(1)(b).