Reg43 Rev2 Ann3 fig 21
11.2.4.2. The load mass shall be 28.7 . t2 g where t is the thickness in mm of the test specimen. The resulting stress on the outer fibre of the sample is approximately 6.9 MPa.
Example: For a 3 mm thick sample placed horizontally between a downward fixed edge and an upward fulcrum edge separated by 51 mm the applied downward load at 102 mm from the fulcrum is to be 258 g.
11.2.4.3. While the sample is stressed, one of the prescribed chemicals shall be applied to the top surface of the sample above the fulcrum point. The chemical shall be applied with a soft, 13 mm wide brush, wetted before each stroke. Ten individual strokes at 1 s intervals across the width of the sample, avoiding the end and edges, shall be required (see Figure 22).