Solid fuel heaters
(1) Must comply with AS/NZS 4013:1999, Domestic solid fuel burning appliances—Method for determination of flue gas emission.
(2) Rain excluders must not impede the vertical flow of exhaust gases.
(3) Must be installed in accordance with AS/NZS 2918:2001, Domestic solid fuel burning appliances—Installation.
(4) Chimney or flue must be a minimum of 300mm above any structure within a 3.6m horizontal radius.
(5) Top of chimney or flue must be at least 1m higher than any other building within a 15m radius.
(6) Maximum height of chimney or flue—6m above roof.