Renewable Energy (Method for Solar Water Heaters) Determination 2016
Division D - NotesDivision D - Notes
Start here
Get a plain-English read of Division D - Notes
Turn the raw legal text into a practical explanation grounded in Renewable Energy (Method for Solar Water Heaters) Determination 2016.
Division D - Notes
Pump cycling and simulation stability
For pumped SWHs the pump controller may cycle the pump on/off if the ratio Ton/Toff is too small. See Duffie & Beckman, "Solar Engineering of Thermal Processes", Section 10.4 Controls for more detail [1] and how to calculate the required Ton/Toff ratio to avoid pump cycling.
Modelling an in-tank coil heat exchanger for the solar circulation loop using the Type 60 tank model can lead to convergence problems in TRNSYS 15, particularly for glycol-water mixtures. Using water as the HX fluid instead and/or artificially increasing the collector flow rate may overcome this problem. Changing the heat transfer fluid and/or flow rate will introduce an error, and the increase in flow rate should be kept as small as possible.
Batching multiple TRNSYS rating Calculations
Running multiple TRNSYS decks can be automated by using a Windows batch file. For example, four decks (deckfilenameZ1 to deckfilenameZ4) can be run successively by writing the following lines into a Notepad file (note the spaces) and saving the file with .bat extension.
C:\Trnsys15\trnsys.exe deckfilenameZ1.dck /N
C:\Trnsys15\trnsys.exe deckfilenameZ2.dck /N
C:\Trnsys15\trnsys.exe deckfilenameZ3.dck /N
C:\Trnsys15\trnsys.exe deckfilenameZ4.dck /N
Right-clicking the batch file allows to one to edit it, left clicking or double clicking will run it.
References
[1] Duffie, J. A. and Beckman, W. A., Solar Engineering of thermal processes, 3rd ed., Wiley, New York, 2006.