What it does
This instrument is a class licence made under section 132 of the Radiocommunications Act 1992 (the Act). It authorises the operation of body scanners that use millimetre-wave radiofrequency technology for aviation security screening at security‑controlled airports, and for training purposes. Instead of requiring each body scanner to hold an individual apparatus licence, the class licence provides a standing authorisation to any person who meets the conditions set out in sections 7 and 8, provided they fall within the defined categories of authorised persons. Mechanically, the licence replaces a case‑by‑case licensing process with a set of standardised permissions and prohibitions. This reduces administrative costs for the Australian Communications and Media Authority (ACMA) and for airport operators, but it also constrains operators to specific technical parameters and operational settings that cannot be varied by negotiation.
The licence covers two defined frequency ranges: 24.25 GHz to 30 GHz, and 67 GHz to 80 GHz. Power limits differ between the two bands. For the lower band, the maximum instantaneous equivalent isotropically radiated power (EIRP) is -10 dBm, with a power spectral density limit of -10 dBm per 4 MHz. For the upper band, the maximum instantaneous EIRP is 7 dBm, with a power spectral density limit of 7 dBm per 1 MHz. These are relatively low power levels, reflecting that millimetre-wave scanners are short‑range devices that operate indoors. The class licence also requires that any body scanner operated under it must be used indoors at a security‑controlled airport. That geographic and physical constraint limits the opportunity for interference with other radiocommunications services but also ties the authorisation to a specific infrastructure type.
Crucially, the class licence does not provide protection from interference for any receiver tuned to the body scanner’s transmitter. As the note to section 6 points out, the body scanner will operate in parts of the radiofrequency spectrum that are expected to be used by other devices. A radiocommunications receiver tuned to the body scanner’s transmitter will not be afforded protection from interference caused by other radiocommunications devices. This means that if another licensed or class‑licensed device causes interference to the body scanner, the scanner operator has no recourse under the Act. Conversely, the scanner operator must not cause interference to other radiocommunications services (section 7(5)). That asymmetry places the entire risk of harmful interference on the scanner operator, which is a significant compliance burden that may not be immediately obvious to airport operators or screening authorities.