Plumbing and Drainage Regulation 2019
sch.6-sec.3Documents for other work
Start here
Get a plain-English read of sch.6-sec.3
Turn the raw legal text into a practical explanation grounded in Plumbing and Drainage Regulation 2019.
sch.6-sec.3 Documents for other work
This section applies to an application for, or to amend, a permit for work for premises, other than to the extent the work relates to a class 1a or 10a building. The application must be accompanied by 1 or more plans of the premises showing— the location of any existing or proposed building or structure on the premises; and for a proposed building— a floor plan showing any proposed sanitary fixtures; and the elevations; and the location on the premises, and dimensions, of each connection point to— a service provider’s water supply system; and any other supply of water; and a sewerage system; and the invert levels, and finished surface levels, at each connection point mentioned in paragraph (c) ; and the finished surface level for each overflow relief gully; and the location on the premises of any of the following that is to result from, or be affected by, the work— all water meters and supply pipes; all fixtures, reflux valves, overflow relief gullies, and sanitary drains; the access points for cleaning and maintaining plumbing and drainage; any testable backflow prevention devices; and for work on a class 1 building on a lot that is part of a community titles scheme, or on a class 2 to 9 building—details of the specifications of each water meter on the lot or for the building. If the proposed work involves installing sanitary drainage, the application must also be accompanied by— a site classification report, complying with AS 2870—2011, for the premises; and if the soil classification for the premises under AS 2870—2011 is H, E or P—a design showing the articulation of the sanitary drainage for the premises. sch 6 s 3 amd 2022 SL No. 171 s 16 (sch.6-sec.3-ssec.1) This section applies to an application for, or to amend, a permit for work for premises, other than to the extent the work relates to a class 1a or 10a building. (sch.6-sec.3-ssec.2) The application must be accompanied by 1 or more plans of the premises showing— the location of any existing or proposed building or structure on the premises; and for a proposed building— a floor plan showing any proposed sanitary fixtures; and the elevations; and the location on the premises, and dimensions, of each connection point to— a service provider’s water supply system; and any other supply of water; and a sewerage system; and the invert levels, and finished surface levels, at each connection point mentioned in paragraph (c) ; and the finished surface level for each overflow relief gully; and the location on the premises of any of the following that is to result from, or be affected by, the work— all water meters and supply pipes; all fixtures, reflux valves, overflow relief gullies, and sanitary drains; the access points for cleaning and maintaining plumbing and drainage; any testable backflow prevention devices; and for work on a class 1 building on a lot that is part of a community titles scheme, or on a class 2 to 9 building—details of the specifications of each water meter on the lot or for the building. (sch.6-sec.3-ssec.3) If the proposed work involves installing sanitary drainage, the application must also be accompanied by— a site classification report, complying with AS 2870—2011, for the premises; and if the soil classification for the premises under AS 2870—2011 is H, E or P—a design showing the articulation of the sanitary drainage for the premises.