25F Clause 5.3.9 modified (1) After clause 5.3.9, heading Note Paragraphs (a)(2), (b)(4), (c), (c1) and (f) of this clause have no effect in this
Regulations 2016 34 (2) Clause 5.3.9(a) (a) This clause 5.3.9 applies where a Generator proposes to alter a connected generating system or a generating system where that alteration would affect performance standards in an existing connection agreement and that alteration: (1) will affect the performance of the generating system relative to any of the technical requirements set out in jurisdictional electricity legislation within the constraints allowed under jurisdictional electricity legislation; or (2) will, in AEMO's reasonable opinion, have an adverse system strength impact; or (3) will, in NTESMO's reasonable opinion, adversely affect network capability, power system security, quality or reliability of supply, inter-regional power transfer capability or the use of a network by another Network User. Note purposes of paragraph (a)(1) will be requirements that correspond to the matters set out in clauses S5.2.5 to 5.2.8 in the Rules applying in other participating jurisdictions. The application of paragraph (a)(1) will be revisited as part of the (3) Clause 5.3.9(b) omit AEMO (4) Clause 5.3.9(b)(2) omit in accordance with the Power System Model Guidelines, Power System Design Data Sheet and Power Setting Data Sheet
Regulations 2016 35 (5) Clause 5.3.9(d) (d) Without limiting paragraph (a), a proposed alteration to the following equipment is deemed to affect the performance of the generating system relative to technical requirements, thereby necessitating a submission under subparagraph (b)(3), unless NTESMO and the Network Service Provider otherwise agree: (1) machinery windings; (2) power converter; (3) reactive compensation plant; (4) excitation control system; (5) voltage control system; (6) governor control system; (7) power control system; (8) protection system; (9) auxiliary supplies; (10) remote control and monitoring system. (6) Clause 5.3.9(e) omit other Network Service Providers and AEMO and other Network Service Providers (7) Clause 5.3.9(g) and (h) AEMO
Regulations 2016 36