156 Footings
156 Footings
(1) A relocatable home or associated structure must be installed on footings if required by the engineer’s certificate for the home or structure.
(2) The footings and tie-down system for the relocatable home or associated structure must be constructed in accordance with the engineer’s certificate.
(3) The clearance beneath the home or structure must—
(a) provide adequate underfloor cross-flow ventilation, and
(b) be measured from the lowest point of the underside of the home’s chassis or frame, and
(c) be—
(i) if termite shields are required to be installed—at least 400 millimetres, or
(ii) otherwise—at least 200 millimetres, or
(iii) a lesser clearance specified in the approval.