Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019
33Meaning of SEER rating
Start here
Get a plain-English read of 33
Turn the raw legal text into a practical explanation grounded in Greenhouse and Energy Minimum Standards (Air Conditioners up to 65kW) Determination 2019.
33 Meaning of SEER rating
commercial SEER rating means a SEER rating calculated:
(a) using the commercial-based temperature bins set out in section 1 of Schedule 6; and
(b) according to subclause 6.2 of AS/NZS 3823.4.1:2014 and AS/NZS 3823.4.2:2014, using the t0 and t100 values set out in section 2 of Schedule 6 for the purposes of Formula 2.
residential SEER rating means a SEER rating calculated in accordance with Division 2 of this Part.
SEER rating (short for Seasonal Energy Efficiency Ratio rating) means any of the following:
(a) the Total Cooling Seasonal Performance Factor (TCSPF);
(b) the Heating Seasonal Performance Factor (HSPF);
(c) the Cooling Season Total Energy Consumption;
(d) the Heating Season Total Energy Consumption.
Note: For each SEER rating, there will be 6 values, one for each temperature zone (hot, average and cold) relating to residential use of the product, and one value for each temperature zone relating to commercial use of the product.