Part 7 — Saving and repeal
-
Savings for repealed regulations 40
-
Repeal 40
Schedule 2 — Forms
Schedule 3 — Witness fees and allowances
-
Daily allowance 45
-
Expenses 45
-
Expert evidence 45
Schedule 4 — Fees for permits and authorisations
Schedule 5 — Classes of gasfitting work
Schedule 6 — Certain requirements as to consumers’ gas installations
Division 1 — Interpretation
- Terms used 48
Division 3 — LPG cylinders and tanks
-
Location of cylinders, tanks and regulators 49
-
Housings for cylinders 49
-
Pressure relief valve outlets, position of 49
-
Appliances not to be connected to gas supply for mobile engines 50
Division 4 — Fitting lines and fittings
-
Fitting lines and fittings 50
-
PVC or PE fitting lines 50
-
Pressure holding capability of consumer’s gas installations 51
-
Protection from excessive pressure 51
Division 5 — Appliances generally
-
Appliances to be approved 51
-
Appliances not to be connected to wrong type of gas 52
-
Avoidance of hazards 52
-
Certain appliances not to be installed in certain rooms 52
-
Safety devices required for certain appliances 53
-
Flues 54
-
Hoods or canopies 54
-
Electrical apparatus in appliances 54
Division 6 — Additional requirements for particular appliances
-
Cooking appliances, fryers etc. 55
-
Water heaters 56
-
Space heating appliances 56
604A. Flueless gas space heaters in schools and child care centres 57
- Swimming pool heaters 58
Division 7 — Caravans
-
Application of this Division 58
-
Location of appliances 58
-
Pressure 59
-
Warnings 59
Division 8 — Marine craft
-
Application of this Division 60
-
Cylinders and their valves to be accessible 60
-
Cylinders and their compartments 60
-
Appliances etc. not be installed in some places 61
-
Fitting lines, location of 61
-
Appliances, location of 61
-
Pressure 62
-
Ventilation 62
-
Flues 63
-
Water or room heaters 63
-
Cooking appliances 64
-
Warnings 64
Schedule 7 — Standards containing requirements for consumers’ gas installations
Notes
Compilation table 67
Other notes 70
Defined terms
Gas Standards Act 1972
Gas Standards (Gasfitting and Consumer Gas Installations) Regulations 1999
Part 1 — Preliminary
1. Citation
These regulations may be cited as the Gas Standards (Gasfitting and Consumer Gas Installations) Regulations 1999.
2. Commencement
These regulations come into operation on the day on which they are published in the Gazette.
3. Terms used
(1) In these regulations, unless the contrary intention appears —
apparatus means any measuring device, pressure raising device, regulator, valve, instrument, or other device used to measure, control, or regulate gas supply to any appliance or gas fitting;
appliance means an appliance that consumes gas for any purpose;
approved means approved by the Director;
AS followed by a designation consisting of a number, refers to the text, as from time to time amended and for the time being in force, of the document so designated, published by Standards Australia;
AS/NZS followed by a designation consisting of a number, refers to the text, as from time to time amended and for the time being in force, of the document so designated, jointly published by Standards Australia and Standards New Zealand;
authorisation means an authorisation issued under regulation 12 or continued in force under regulation 43;
caravan means a structure designed or adapted to be towed or transported from one place to another and intended for human habitation or use as a workplace and includes the following —
(a) a self‑propelled recreational vehicle or mobile home;
(b) an associated annex or similar structure whether permanently or temporarily attached to or adjoining the main part of the structure;
certificate of competency means a certificate of competency continued in force under regulation 43;
Class, in relation to gasfitting work, means a class of gasfitting work referred to in regulation 13(2) and set out in Schedule 5;
fitting means a device used —
(a) to join pipes or flues; or
(b) to change the direction or diameter of a pipe or flue; or
(c) to provide a branch in a pipe or flue; or
(d) to terminate a pipe or flue;
fitting line means —
(a) if gas is supplied through a cylinder, any pipe, fitting, or any part of a pipe or fitting, beyond the cylinder; or
(b) if gas is supplied from a reticulated system, any pipe or fitting, or any part of a pipe or fitting, beyond the point of supply that is used or intended to be used to convey gas;
flue means the duct, conduit or passage through which products of combustion are or are intended to be conveyed to a flue terminal;
flue gas means the products of combustion produced by an appliance that is designed to discharge products of combustion through a flue;
flue terminal means the point at which flue gas discharges from the flue;
gas fitter means —
(a) a registered gas fitter; or
(b) a supervised gas fitter;
gas supplier means —
(a) an undertaker; or
(b) a pipeline licensee; or
(c) an operator of a reticulated gas supply system; or
(d) a person who supplies gas through a pressurized container;
LPG means a mixture of hydrocarbons in liquid or vapour form, consisting mainly of butane, butene, propane, or propene, or any mixture of those substances;
master meter means a meter used to measure the amount of gas supplied to the point at which delivery of the gas is made to the consumer;
maximum hourly input rate, in relation to an appliance, is the energy usage of the appliance in one hour when it is operating at its maximum level of gas consumption under normal operating conditions;
meter means a device used to measure the amount of gas passing through the device;
mobile engine means a gas‑fuelled engine that —
(a) is mounted in or on any vehicle, craft or portable appliance; and
(b) is supplied by fuel from a cylinder or tank mounted on or in the vehicle, craft or portable appliance;
natural gas means a hydrocarbon gas, in liquefied or vapour form, consisting mainly of methane;
notice of completion means a notice of completion under regulation 28(3);
permit means a permit issued under regulation 12 or continued in force under regulation 43;
pressure raising device, in relation to a consumer’s gas installation, means —
(a) a fan, blower or other device to enable the pressure of the gas in the installation, or any part of it, to be raised; or
(b) any device that may reduce the pressure at the inlet to the master meter;
registered gas fitter means —
(a) in relation to doing gasfitting work — a person who is registered as the holder of a certificate of competency, a permit or an authorisation to do the work; or
(b) in relation to supervising gasfitting work — a person who is authorised under Part 3A Division 1 to supervise the work;
regulator means a device that automatically controls the pressure or volume of gas available beyond the point at which the device is installed;
servicing, in relation to a consumer’s gas installation, means —
(a) maintenance involving the adjustment and cleaning of any appliance or apparatus in the installation in accordance with the recommendations of the manufacturer; or
(b) repair involving the exchange of components but not requiring modification of the installation;
supervised gas fitter, in relation to gasfitting work, means —
(a) a person who does the work in a prescribed capacity under regulation 6; or
(b) a person who does the work under a permit that authorises the person to do the work, but only with supervision;
Note for this definition:
A person who is a supervised gas fitter in relation to particular gasfitting work may be a person who supervises gas fitters in relation to other gasfitting work.
Type B appliance means an appliance that has a maximum hourly input rate exceeding 10 MJ but is neither a Type A gas appliance nor a mobile engine;
valve means a device for controlling or shutting off the flow of gas.
(2) In these regulations, unless the contrary intention appears, the numerical values prescribed are subject to tolerances according to normal trade practice.
(3) Unless the contrary intention appears a reference in these regulations to the volume of a room or space is to be read as a reference to the volume that may be enclosed and includes the volume of any adjoining room or space that is not able to be separated by a door or other means of enclosure.
[Regulation 3 amended: Gazette 19 Dec 2000 p. 7275; 21 Apr 2006 p. 1575; 30 Nov 2007 p. 5934; 26 Nov 2010 p. 5929; 8 Jan 2015 p. 99‑100; SL 2020/196 r. 31; SL 2021/86 r. 35; SL 2023/147 r. 4.]
4. Gasfitting work, defined
A reference in these regulations to gasfitting work is to be read as a reference to an operation, work or process in connection with the installation, removal, demolition, replacement, alteration, maintenance, or repair of a gas installation except —
(a) the replacement of LPG cylinders, compressed natural gas cylinders or liquefied natural gas cylinders; or
(b) any operation, work or process in relation to a mobile engine that does not involve or affect any fitting line or apparatus; or
(c) an adjustment of the air‑fuel ratio of a mobile engine that does not involve the disconnection or dismantling of any fitting line or apparatus; or
(d) an operation, work or process carried out in connection with a reticulated supply system for the gas supplier.
[Regulation 4 amended: Gazette 21 Apr 2006 p. 1575.]
5. Work etc. in nature of gasfitting prescribed (Act s. 13A(2))
For the purposes of section 13A(2) of the Act, doing or supervising any gasfitting work is of the nature of gasfitting.
6. Capacity prescribed (Act s. 13A(2))
For the purposes of section 13A(2) of the Act, a person does gasfitting work in a prescribed capacity if the person —
(a) does not hold a certificate of competency, a permit or an authorisation that authorises the person to do the work; and
(b) does the work under the supervision of a registered gas fitter who is authorised under Part 3A Division 1 to supervise the work.
[Regulation 6 inserted: SL 2023/147 r. 5.]
Part 2 — Administration
7. Particulars for register prescribed (Act s. 13A(4))
For the purposes of section 13A(4) of the Act, the register must contain the following particulars for each registered person —
(a) the name and residential address of the person;
(b) the identifying number and the grade or kind of the certificate of competency, permit or authorisation, as the case may be;
(c) the date on which the certificate, permit, or authorisation was issued and, if applicable, the date on which it will expire.
8. Gas fitter must give notice of change of address
A registered gas fitter must, within 14 days of a change to the address of the registered gas fitter provided to the Director, give the Director written notice of the new address.
[Regulation 8 inserted: SL 2022/121 r. 10.]
9. Inquiries etc., matters prescribed for (Act s. 13A)
(1) For the purposes of section 13A(3)(e) of the Act, the Director is authorised to delegate his or her power to deal with a matter summarily under section 13A(11) of the Act to a person or body of persons appointed by the Director, and the exercise of that power by that person or persons is authorised.
(2) For the purposes of section 13A(12)(c) of the Act, a summons requiring the attendance of a holder as defined in section 13A(12) of the Act must be in the form of Form 1 in Schedule 2.
(3) For the purposes of section 13A(12)(c) of the Act, a summons requiring the attendance of a person to give evidence or produce documents at proceedings must be in the form of Form 2 in Schedule 2.
(4) A person who attends at proceedings under section 13A of the Act is entitled to receive a fee or allowance in accordance with Schedule 3.
[Regulation 9 amended: Gazette 30 Dec 2004 p. 6988‑9.]
[10. Deleted: Gazette 30 Dec 2004 p. 6989.]
Part 3 — Permits and authorisations
11. Applications for permits and authorisations (Act s. 13A(6))
For the purposes of section 13A(6) of the Act, a person may apply for a permit or an authorisation to carry out gasfitting work by sending to the Director an application in an approved form, accompanied by —
(a) if the application is for a permit — the relevant application and issuance fees set out in Schedule 4; and
(b) if the application is for an authorisation — the relevant application fee set out in Schedule 4.
[Regulation 11 amended: Gazette 22 Dec 2017 p. 5987; SL 2020/196 r. 32; SL 2023/147 r. 6.]
12. Issue of permits and authorisation
(1) The Director may issue a permit or an authorisation to an applicant to carry out the gasfitting work specified in the permit or authorisation if the Director is satisfied that the applicant —
(a) has adequate theoretical and practical knowledge and adequate skills, to carry out the gasfitting work; and
(b) has an adequate knowledge of the Act and these regulations; and
(c) is otherwise a fit and proper person to carry out the gasfitting work.
(2) If the applicant has not applied for a particular permit or a particular authorisation, or has applied for a permit or an authorisation that the Director thinks is not appropriate having regard to the qualifications and experience of the applicant and the nature of the gasfitting work, the Director may issue a permit or an authorisation that the Director thinks is appropriate in the circumstances.
(3) A permit or an authorisation has effect only for the period specified in the permit or the authorisation.
[Regulation 12 amended: SL 2023/147 r. 7.]
13A. Replacing lost etc. permits and authorisations
(1) If the Director is satisfied that a permit or an authorisation has been lost, defaced, mutilated or destroyed the Director may, on application in writing to the Director and payment of the appropriate fee set out in Schedule 4, issue to the holder a replacement permit or authorisation.
(2) The Director may decline to issue a replacement permit or authorisation that has been defaced or mutilated until the defaced or mutilated permit or authorisation is returned to the Director.
(3) A replacement for a permit or authorisation issued under this regulation is to be regarded for the purposes of these regulations as if it were the original permit or authorisation for which it is a replacement.
[Regulation 13A inserted: Gazette 26 Nov 2010 p. 5929-30.]
13. Grades of permit or authorisation
(1) A permit or an authorisation issued under regulation 12 is to be of a grade designated by reference to the class or classes of gasfitting work referred to in subregulation (2) that the permit or authorisation authorises the holder to do.
(2) For the purposes of these regulations gasfitting work is to be regarded as of one of the classes set out in Schedule 5.
[Regulation 13 amended: SL 2023/147 r. 8.]
14. Restrictions etc. on permits or authorisations
The Director may endorse on any permit or authorisation any restriction, limitation, condition or extension as to the authority conferred in the permit or authorisation.
15. Effect of permits
(1) A permit authorises the holder to do the gasfitting work specified in the permit.
[(2),(3) deleted]
(4) A permit continues to have effect on and from the day on which it was issued or renewed for the period, not exceeding 5 years, specified in the permit.
[Regulation 15 amended: Gazette 26 Nov 2010 p. 5930; 22 Dec 2017 p. 5987; 2 Oct 2018 p. 3784; SL 2023/147 r. 9.]
15A. Renewal of permits
(1) The Director may renew a permit on an application made not earlier than 90 days before, and not later than 30 days after, the date of the expiry of the permit.
(2) An application is made under subregulation (1) by submitting to the Director, together with the appropriate fee set out in Schedule 4, the form, duly completed, made available by the Director.
(3) If, at least 12 months before the date of the expiry of the permit, the Director gives to the holder written notice that the holder is required to complete successfully a course specified in the notice relating to the safe performance of gasfitting work, the Director may refuse to renew the permit if the holder fails to comply with that requirement before that date.
(4) Subject to subregulation (5), if a permit is renewed under subregulation (1), the renewal has effect from the time when, but for the renewal, the permit would have expired.
(5) Where a permit is renewed under subregulation (1) on an application made within 30 days after the permit expires, the renewal —
(a) has effect only for the balance of the period specified in the permit remaining after the registration is renewed; and
(b) does not affect the illegality of anything done after the registration expired and before the renewal took effect.
(6) In subregulation (5), the reference to the period specified in the permit includes that part of the period in effect immediately before the Gas Standards (Gasfitting and Consumer Gas Installations) Amendment Regulations (No. 2) 2017 regulation 6 came into operation.
[Regulation 15A inserted: Gazette 22 Dec 2017 p. 5988.]
16. Effect of authorisations
(1) An authorisation authorises the holder to do the specified gasfitting work for the specified employer.
[(2) deleted]
(3) In this regulation —
employer, in relation to the holder of an authorisation, includes a person who has engaged the holder under a contract for services;
specified means specified in the authorisation.
[Section 16 amended: SL 2023/147 r. 10.]
Part 3A — Supervision of gasfitting
[Heading inserted: SL 2023/147 r. 11.]
Division 1 — Authority to supervise gasfitting work
[Heading inserted: SL 2023/147 r. 11]
16A. Certificate of competency and permit holders supervising Class G, E or P gasfitting work
(1) In this regulation —
relevant gasfitting work means Class G, E or P gasfitting work;
supervisee means a person who —
(a) holds a certificate of competency or permit that authorises the person to do gasfitting work of any class with or without supervision; and
(b) is doing gasfitting work in a class of relevant gasfitting work for the purpose of gaining adequate knowledge and skill to be eligible for a permit to do gasfitting work of that class without supervision.
(2) A certificate of competency or permit authorises the holder to supervise relevant gasfitting work if —
(a) the relevant gasfitting work is work that the certificate or permit authorises the holder to do; and
(b) the certificate or permit does not have a restriction, limitation or condition endorsed on it that would require the holder, if the holder were to do the relevant gasfitting work themselves, to be supervised while doing the work; and
(c) the holder’s supervision of the relevant gasfitting work does not conflict with any restriction, limitation or condition endorsed on the certificate or permit; and
(d) the person doing the relevant gasfitting work is a supervisee.
[Regulation 16A inserted: SL 2023/147 r. 11.]
16B. Certificate of competency and permit holders supervising Class I gasfitting work
A certificate of competency or permit authorises the holder to supervise Class I gasfitting work if —
(a) the gasfitting work is work that the certificate or permit authorises the holder to do; and
(b) the certificate or permit does not have a restriction, limitation or condition endorsed on it that would require the holder, if the holder were to do the gasfitting work themselves, to be supervised while doing the work; and
(c) the holder’s supervision of the gasfitting work does not conflict with any restriction, limitation or condition endorsed on the certificate or permit.
[Regulation 16B inserted: SL 2023/147 r. 11.]
16C. Authorisation holders supervising gasfitting work
(1) In this regulation —
employer, in relation to the holder of an authorisation, includes a person who has engaged the holder under a contract for services.
(2) An authorisation authorises the holder to supervise gasfitting work if —
(a) the gasfitting work is being done for the employer specified in the authorisation; and
(b) the gasfitting work is work that the authorisation authorises the holder to do; and
(c) the authorisation does not have a restriction, limitation or condition endorsed on it that would require the holder, if the holder were to do the gasfitting work themselves, to be supervised while doing the work; and
(d) the holder’s supervision of the gasfitting work does not conflict with any restriction, limitation or condition endorsed on the authorisation.
[Regulation 16C inserted: SL 2023/147 r. 11.]
Division 2 — Duties of person supervising gasfitting work
[Heading inserted: SL 2023/147 r. 11]
16D. Duties of person supervising supervised gas fitter
A registered gas fitter supervising gasfitting work must ensure that —
(a) the person doing the gasfitting work complies with these regulations; and
(b) the gasfitting work is work that the registered gas fitter is authorised to supervise under Division 1.
[Regulation 16D inserted: SL 2023/147 r. 11.]
Part 4 — Performance of gasfitting
17. Terms used
In this Part —
commission, in relation to a gas installation, means connect the installation so that it is available for use;
notice of defects means a notice of defects under regulation 29.
18. Gas fitters, duties of as to gasfitting work
(1) A gas fitter who does gasfitting work on a gas installation must ensure that the work is done in a safe manner.
(2) The gas fitter must ensure that —
(a) every part of the gas installation on which the work was done or that is affected by the work —
(i) complies with the requirements referred to in regulation 32; and
(ii) is safe to use;
and
(b) the work is completed to a trade finish.
(3) Subregulation (2) does not require the gas fitter to make an assessment about —
(a) whether the design of an appliance complies with the requirements referred to in regulation 32; or
(b) the efficacy of the design of an appliance.
[Regulation 18 inserted: Gazette 19 Dec 2000 p. 7275‑6.]
[19. Deleted: SL 2023/147 r. 12.]
20. Installing etc. appliances etc., gas fitters’ duties as to
(1) When a gas fitter installs in a gas installation an appliance or apparatus, part of an appliance or apparatus or a part of the installation the gas fitter must install the appliance, apparatus or part —
(a) in a suitable place; and
(b) in accordance with any instructions or recommendations of the manufacturer or designer relating to the installation of that appliance, apparatus or part.
(2) A gas fitter must not install a used appliance, whether or not it has been repaired or reconditioned, in a consumer’s gas installation unless the gas fitter has checked the appliance and ascertained that it operates safely.
(3) When a gas fitter installs a used appliance the gas fitter must endorse on the notice of completion a note to the effect that the gas fitter ascertained that it was operating safely.
(4) A gas fitter must not install an appliance that has been modified in any way unless the modification has been specifically approved for the individual appliance by the Director or an inspector.
(4a) A gas fitter must not modify in any way an appliance that has been installed unless the modification has been specifically approved for the individual appliance by the Director or an inspector.
(5) A gas fitter must not install in a consumer’s gas installation an appliance that uses, in addition to the gas supplied from a reticulated system, any gas that is under pressure unless —
(a) the gas supplier has approved the installation of the appliance; and
(b) the appliance is fitted with a device approved by the gas supplier to prevent the entry into the reticulated supply system of the gas; and
(c) the gas fitter has notified the consumer of the consumer’s obligation under regulation 36(4) to permit the gas supplier to inspect and test the appliance.
(6) A gas fitter must not install a pressure raising device in a consumer’s gas installation unless —
(a) the gas supplier has approved the installation; and
(b) any safety device required by the gas supplier is fitted to the satisfaction of the gas supplier; and
(c) the gas fitter has notified the consumer of the consumer’s obligation under regulation 36(5) to permit the gas supplier to inspect and test the pressure raising device and any safety device required under paragraph (b).
[Regulation 20 amended: Gazette 19 Dec 2000 p. 7276.]
21. Commissioning appliances, gas fitters’ duties as to
When a gas fitter commissions an appliance the gas fitter must —
(a) adjust it for safe and correct operation; and
(b) if the consumer is present, demonstrate to the consumer the correct method of operating the appliance; and
(c) attach to the appliance in a conspicuous position all instructions issued by the manufacturer as to the correct method of operating the appliance.
22. Type B appliances, permanent connection of
(1) A gas fitter must not leave a Type B appliance permanently connected in a consumer’s gas installation unless an inspector has issued a certificate of compliance for the appliance under regulation 22A.
(2) For the purposes of subregulation (1), an appliance is not to be regarded as permanently connected if it is connected for a period approved in writing by an inspector pending inspection of the appliance by that inspector.
(3) For the purposes of subregulation (2), an inspector may approve a period of no more than —
(a) 28 days; or
(b) if in a particular case a longer period is required and the inspector gives written notice to the Director of the approval — 90 days.
(4) The Director may, in a particular case, extend a period approved under subregulation (3)(a) or (b).
[Regulation 22 inserted: Gazette 19 Dec 2000 p. 7276‑7.]
22A. Type B appliances, inspection and certification of
(1) An inspector may issue a certificate of compliance for a Type B appliance if the inspector has inspected the appliance and ascertained, so far as is practicable, that it complies with the requirements referred to in regulation 32.
(2) The certificate of compliance is issued by —
(a) giving the certificate in an approved form to the Director; and
(b) giving copies of the certificate to the relevant persons under subregulation (4) or (5); and
(c) attaching an approved badge or label to the appliance in a conspicuous position.
(3) The appliance may be inspected —
(a) at the place where the appliance is installed and commissioned; or
(b) if the Director so approves, at any other place.
(4) If the inspection is carried out at the place where the appliance is installed and commissioned, a copy of the certificate of compliance is to be given to each of the following persons —
(a) the gas fitter who commissioned the appliance;
(b) the consumer for whom the appliance was installed and commissioned;
(c) the gas supplier.
(5) If the inspection is carried out at any other place under subregulation (3)(b), 3 copies of the certificate of compliance are to be given to the manufacturer.
(6) When the manufacturer of the appliance receives 3 copies of a certificate of compliance under subregulation (5) and the appliance is subsequently installed and commissioned in a consumer’s gas installation, the manufacturer must give a copy of the certificate to each of the following persons —
(a) the gas fitter who commissioned the appliance;
(b) the consumer for whom the appliance was installed and commissioned;
(c) the gas supplier.
[Regulation 22A inserted: Gazette 19 Dec 2000 p. 7277.]
23. Servicing gas installations, gas fitters’ duties as to
(1) When a gas fitter services a consumer’s gas installation the gas fitter must record the service information.
(2) The service information must be —
(a) clearly and legibly displayed in permanent form on a badge or label attached to the consumer’s gas installation; or
(b) recorded in accordance with an approval under subregulation (3).
(3) The Director may, in a particular case or class of case, approve in writing another means of recording service information for a consumer’s gas installation.
(4) In this regulation —
service information, in relation to the servicing of a consumer’s gas installation, means —
(a) the date that the servicing took place; and
(b) the identification number endorsed on the certificate of competency, permit or authorisation held by the registered gas fitter who did or supervised the servicing.
24. Inaccessible fitting lines, gas fitters’ duties as to
If a fitting line is in a location where it will not be readily accessible when in use, the gas fitter must ensure that before the fitting line becomes inaccessible —
(a) all joints are welded or brazed; and
(b) the line is pressure tested in accordance with these regulations.
25. Fitting lines to be clean
(1) A gas fitter must ensure that a fitting line is thoroughly clean inside before it is installed.
(2) At the end of each day’s work on a consumer’s gas installation the gas fitter must ensure that —
(a) any open end of any fitting line is temporarily sealed against the entry of foreign matter; and
(b) such other precautions are taken as are necessary to prevent the entry of foreign matter into the fitting line.
26. Pressure testing gas installations
(1) If a gas fitter installs or does any work on a consumer’s gas installation, the gas fitter must ensure that, before the installation is commissioned —
(a) the requirements of these regulations as to pressure testing are satisfied and the system is made gas‑tight; and
(b) if the gas supply is available for connection, the system is purged of all air or other gas except the gas on which the system is to operate.
(2) The gas fitter must not use a medium except one of the following for pressure testing or for locating a leak in a consumer’s gas installation —
(a) air;
(b) carbon dioxide;
(c) nitrogen;
(d) the gas proposed to be used in the consumer’s gas installation;
(e) such other medium as is approved in writing by the Director or an authority recognized by the Director as a competent authority for that purpose.
(3) If the use of water is approved under subregulation (2)(e), the person testing the consumer’s gas installation must ensure that the water is thoroughly removed from the installation before it is commissioned.
[27. Deleted: Gazette 21 Apr 2006 p. 1576.]
28. Completion of gasfitting work, gas fitters’ duties on
(1) This regulation applies to a registered gas fitter who does or supervises particular gasfitting work or a particular part of gasfitting work to be done on the whole or part of a gas installation except —
(a) servicing a consumer’s gas installation; or
(b) gasfitting work to rectify a defect specified in a notice of defects.
(2) When the particular gasfitting work is completed the registered gas fitter must attach an approved badge or label in an approved place relative to the part of the gas installation on which the work was done or that is affected by the work.
(3) The registered gas fitter must give a notice of completion of the gasfitting work in accordance with this regulation.
(3a) The notice of completion must be given within 48 hours of the completion of the gasfitting work to each of the following —
(a) if the work was done on a mobile gas installation, or the gas supplier cannot be identified — the Director;
(b) if the gas supplier can be identified and the work was not done on a mobile gas installation — the gas supplier;
(c) the person for whom the gasfitting work was done,
or as the Director otherwise approves in a particular case or class of case.
(4) In the notice of completion, the registered gas fitter must certify that he or she has complied with the requirements in regulation 18(2).
(5) The notice of completion is to be in an approved form.
(6) The Director may, in a particular case or class of case, exempt a registered gas fitter from subregulation (2) or (3).
[Regulation 28 amended: Gazette 19 Dec 2000 p. 7278.]
29. Defective gasfitting work, notice of defects to gas fitter
(1) If gasfitting work does not comply with these regulations, an inspector may give a notice of defects to the registered gas fitter who did or supervised the work.
(2) The notice of defects is to be in an approved form.
30. Notice of defects, gas fitter’s duties as to
(1) Unless the registered gas fitter appeals under regulation 31 against a notice of defects, the registered gas fitter must within 7 days —
(a) ensure that the gasfitting work is made to comply with these regulations; and
(b) give a notice of rectification to the inspector that the work has been made to so comply.
(2) The notice of rectification is to be in an approved form.
31. Appeal against notice of defects
(1) A registered gas fitter may, within 48 hours of receiving a notice of defects, appeal in writing to the Director against the notice.
(2) On an appeal under subregulation (1), the Director may confirm, vary or cancel the notice of defects and the Director’s decision is final.
(3) The person must comply with the final decision within 7 days.
Part 4A — Appeals under section 13N(1)(b) of the Act
[Heading inserted: Gazette 30 Nov 2007 p. 5934.]
31A. Terms used
In this Part —
appeal means an appeal under section 13N(1)(b) of the Act;
appellant means a person aggrieved who commences an appeal;
technical review panel means a panel mentioned in section 13N(1)(b) of the Act.
[Regulation 31A inserted: Gazette 30 Nov 2007 p. 5934.]
31B. Technical review panel, convening of etc.
(1) If an appeal is made under section 13N(1)(b) of the Act, the chief executive officer must convene a technical review panel.
(2) The technical review panel is to consist of 3 professional engineers who are competent to deal with the matter the subject of the appeal appointed by the chief executive officer from individuals nominated by the President of the Western Australian Division of The Institution of Engineers Australia.
(3) The chief executive officer must appoint one of the members of the technical review panel to be the chairperson.
(4) The chief executive officer may —
(a) direct that the members of the technical review panel are to be paid remuneration; and
(b) determine the amount of any such payments on the recommendation of the Public Sector Commissioner.
(5) The chief executive officer must provide the technical review panel with such support services as it may reasonably require.
[Regulation 31B inserted: Gazette 30 Nov 2007 p. 5934‑5; amended: Gazette 11 Feb 2011 p. 506‑7.]
31C. Procedure for appeals
(1) An appeal must be commenced by the appellant giving the chief executive officer a notice of appeal.
(2) The notice of appeal must —
(a) be in writing; and
(b) set out the grounds of appeal; and
(c) set out any representations that the appellant wishes to make in support of the appeal.
(3) The notice of appeal must be given to the chief executive officer within 30 days after the day on which the appellant received written notice of the Director’s determination under section 13M(4) of the Act.
(4) The chief executive officer must give the technical review panel the notice of appeal as soon as practicable after the technical review panel is convened.
(5) Subject to subregulation (6), the technical review panel may determine its own procedure.
(6) The technical review panel must give the Director —
(a) a copy of the notice of appeal; and
(b) a reasonable opportunity to make submissions in relation to the appeal.
(7) The technical review panel must complete the review by making a decision under section 13N(3) of the Act within the period specified by the chief executive officer in writing.
(8) The technical review panel must give the appellant and the Director written notice of its decision made under section 13N(3) of the Act.
[Regulation 31C inserted: Gazette 30 Nov 2007 p. 5935.]
Part 5 — Requirements for consumers’ gas installations
32. Consumer’s gas installations, requirements for prescribed (Act s. 13)
(1) For the purposes of section 13 of the Act and subject to regulation 32A and subregulation (4), the requirements that a consumer’s gas installation is required to meet are set out in —
(a) Schedule 6; and
(b) a code or standard set out in Schedule 7 relating to that installation.
(2) To the extent that Schedule 6 modifies, replaces or is inconsistent with the code or standard, Schedule 6 prevails.
(3) The Director may, in relation to a consumer’s gas installation or type of consumer’s gas installation —
(a) vary a requirement prescribed under subregulation (1); or
(b) specify that a requirement prescribed under subregulation (1) does not apply; or
(c) specify a requirement in addition to the requirements prescribed under subregulation (1).
(4) If, on inspection for the purposes of the Act or these regulations, a consumer’s gas installation does not meet the requirements of this regulation because of an amendment to Schedule 7 or to a code or standard set out in Schedule 7, but would have met the requirements of this regulation at some time in the 6 months prior to the day of inspection, the installation is, for the purposes for which the inspection was undertaken, to be taken to have met the requirements of this regulation.
(5) In subregulation (4), the reference to an amendment to Schedule 7 includes a reference to any amendments to these regulations consequential upon the amendment.
[Regulation 32 amended: Gazette 21 Apr 2006 p. 1576; 26 Nov 2010 p. 5930-1.]
32A. Gas installations outside consumer’s land, plan required for
(1) If a part of a consumer’s gas installation is to be located on land that is not owned by that consumer, a written plan detailing the proposed construction, operation and maintenance of that part of the installation is to be submitted to the Director for approval before work on that part of the installation commences.
(2) The Director may approve a plan or, if the Director considers that a plan submitted to the Director for approval is inadequate, the Director may direct that the plan be amended before it is implemented.
(3) If the Director directs that a plan be amended, the plan is to be amended and resubmitted for approval before work on that part of the installation commences.
(4) The part of the consumer’s gas installation that is subject to a plan must be constructed, operated and maintained in accordance with the plan approved by the Director.
[Regulation 32A inserted: Gazette 21 Apr 2006 p. 1576.]
33. Terms used in codes and standards
(1) If a term is defined both in these regulations and in a code or standard specified in regulation 32(1)(b) the definition in these regulations prevails.
(2) A reference in a code or standard to an “Authority” is to be read as a reference to —
(a) the Director; or
(b) if the Director so approves, an inspector.
(3) In AS/NZS 5601 —
(a) a reference to a “consumer billing meter” is to be read as a reference to a master meter; and
(b) a reference to a “sub‑meter” is to be read as a reference to a meter used to measure the amount of gas supplied to a point beyond the master meter.
[Regulation 33 amended: Gazette 19 Dec 2000 p. 7278; 31 Jan 2003 p. 280; 21 Apr 2006 p. 1576; 18 Jan 2011 p. 147.]
Part 6 — Miscellaneous
34. Records about gas fitters, employers to keep
(1) An employer must keep a record in relation to each gas fitter employed to do gasfitting work.
(2) A record must contain —
(a) the name and address of the gas fitter; and
(b) the identifying number and grade of the gas fitter’s certificate of competency, permit or authorisation and any restrictions, limitations, conditions or restrictions on the certificate, permit or authorisation.
(3) The employer must keep a record for at least 2 years after the gas fitter stops being an employee.
(4) The employer must make a record available for inspection by an inspector during normal office hours.
35. Gas suppliers’ duties after gasfitting work on installation that only has Type A gas appliance
(1) Except as provided in this regulation, if gasfitting work is done on a consumer’s gas installation that only includes a Type A gas appliance and that is not supplied with gas, a gas supplier must not supply gas to the installation unless the gas supplier has received a notice of completion of the work.
(2) Subregulation (1) does not apply to gasfitting work done on a consumer’s gas installation associated with a caravan, marine craft or mobile engine.
(3) The Director may, in a particular case or class of case, exempt a gas supplier from subregulation (1).
[Regulation 35 amended: Gazette 19 Dec 2000 p. 7278; 30 Nov 2007 p. 5936.]
35A. Gas suppliers’ duties after gasfitting work on installation that includes Type B appliance
(1) If gasfitting work is done on a consumer’s gas installation that includes a Type B appliance and that is not supplied with gas, a gas supplier must not supply gas to the installation unless the gas supplier —
(a) has received the notice or all notices of completion of the work; and
(b) is satisfied that each appliance in the gas installation complies with clause 501 of Schedule 6.
(2) To avoid doubt, the gas supplier is not prevented by this regulation from imposing other requirements consistent with the Act and these regulations before it supplies gas.
[Regulation 35A inserted: Gazette 19 Dec 2000 p. 7278‑9.]
35B. Gas suppliers’ duties as to Type B appliance in existing gas installation
(1) If —
(a) a Type B appliance is installed in a gas installation that is supplied with gas; or
(b) a Type B appliance, that is installed in a gas installation that is supplied with gas, is modified after a certificate of compliance in relation to the appliance has been issued under regulation 22A,
a person must not cause gas to be supplied to the appliance unless the person is satisfied that the gas supplier has given permission, under subregulation (2), to the gas fitter who is going to conduct the testing and commissioning (or re‑commissioning) of the appliance.
(2) The gas supplier may only give permission for gas to be supplied to the appliance if the gas supplier —
(a) has received the notice or all notices of completion of the work to install or modify the appliance; and
(b) if subregulation (1)(a) applies — is satisfied that each appliance in the gas installation complies with clause 501 of Schedule 6; and
(c) if subregulation (1)(b) applies — has received a copy of the approval of the modification under regulation 20.
(3) To avoid doubt, the gas supplier is not prevented by this regulation from imposing other requirements consistent with the Act and these regulations before it permits the supply of gas.
[Regulation 35B inserted: Gazette 19 Dec 2000 p. 7279.]
36. Consumers’ duties as to gas installations
(1) The consumer for whom a Type B appliance is installed must ensure that the appliance is not used until an inspector has issued a certificate of compliance in relation to the appliance under regulation 22A.
(1aa) The consumer for whom a Type B appliance is modified must ensure that the appliance is made available for testing and commissioning by a gas fitter before the consumer uses the appliance for production purposes.
(1a) The consumer for whom a Type B appliance is modified, after a certificate of compliance in relation to the appliance has been issued under regulation 22A, must ensure that the appliance is not used until an inspector has issued another certificate of compliance in relation to the appliance under that regulation.
(2) If a consumer’s gas installation includes a pressure raising device or an over‑pressure protection device in accordance with clause 406 of Schedule 6, the consumer must ensure that the gas installation is serviced by a registered gas fitter —
(a) within 2 years after the device or fitting line regulator is installed; and
(b) thereafter within 2 years after it was last serviced in accordance with this subregulation.
(3) If a consumer’s gas installation is a mobile engine that uses LPG or natural gas as fuel, the consumer must ensure that the apparatus in the installation is maintained and serviced by a registered gas fitter in accordance with —
(a) in the case of a vehicle mobile engine that uses LPG, AS/NZS 1425; or
(b) in the case of a vehicle mobile engine that uses compressed natural gas, AS 2739; or
(c) in the case of a marine mobile engine that uses LPG, AS 4732; or
(d) in the case of a forklift mobile engine that uses compressed natural gas or LPG, AS 4983.
(4A) If a consumer’s gas installation includes a Type B appliance, the consumer must ensure that the appliance is maintained and serviced by a registered gas fitter in accordance with AS 3814.
(4B) Subregulation (4A) does not apply to a gas installation to which subregulation (3) applies.
(4) If a consumer’s gas installation includes an appliance referred to in regulation 20(5), the consumer must permit the gas supplier to inspect and test the appliance, and the device fitted to it under regulation 20(5)(b), at such times, and as often as, the gas supplier reasonably requests.
(5) If a consumer’s gas installation includes a pressure raising device the consumer must permit the gas supplier to inspect and test the pressure raising device, and any safety device required under regulation 20(6)(b), at such times, and as often as, the gas supplier reasonably requests.
(6) A consumer required by subregulation (2), (3) or (4A) to ensure that the consumer’s gas installation is serviced must make and maintain a record of —
(a) the date on which each service was carried out; and
(b) the registered gas fitter by whom each service was carried out.
(7) A consumer must make a record under subregulation (6) available for inspection by an inspector upon reasonable request.
(8) A record is not required by subregulation (6) to be kept of a service carried out more than 2 years previously.
[Regulation 36 amended: Gazette 19 Dec 2000 p. 7279‑80; 21 Apr 2006 p. 1576‑7; 26 Nov 2010 p. 5931.]
37. Service apparatus not to be installed etc. without owner’s authority
(1) A person, whether or not the holder of a certificate of competency, a permit, or an authorisation, must not install, remove, demolish, replace, alter, maintain, repair, or otherwise interfere with any service apparatus unless the person is authorised in that behalf by the person having the property in that service apparatus.
(2) In subregulation (1) —
service apparatus means any apparatus, works or system, any part of it or any equipment or plant used in conjunction with it that is, is capable of being, or is intended to be used for conveying, measuring, or controlling gas supplied from any distribution works to the position on any premises at which delivery of gas is, is capable of being, or is intended to be, made to a consumer.
38. Misleading statements etc. by gas fitters etc.
(1) A person who is not the holder of a certificate of competency, a permit or an authorisation to do gasfitting work or a particular class of gasfitting work must not advertise or otherwise represent that the person is the holder of that certificate of competency, permit or authorisation.
(2) A gas fitter must not state or otherwise represent to an inspector or any other person that an appliance, apparatus, fitting, design or other thing that is required by these regulations —
(a) to be approved by any person or body; or
(b) to be of a type that is approved by any person or body,
is in fact so approved unless the gas fitter has made reasonable inquiry into the matter and believes that statement or representation to be true.
(3) A gas fitter must not state or otherwise represent that a gas installation complies with the requirements referred to in regulation 32 or is safe to use unless the gas fitter believes on reasonable grounds that statement or representation to be true.
39. Improper use of marks signifying Director’s approval
A person must not mark, stamp or label a gas appliance in a manner that implies or states that the gas appliance is approved, or is of a class or type that is approved, by the Director under section 13D of the Act, or by a body or authority the approval of which the Director has adopted under section 13F of the Act, unless the gas appliance is so approved, or is of a class or type that is so approved.
40. Operators of appliances etc., duties of
A person who operates any appliance, apparatus, or other part of a consumer’s gas installation must take such precautions as are reasonable having regard to any instructions or recommendations of the manufacturer.
41. Boats left unattended, duties of master etc.
Before a petrol‑powered marine craft is left unattended for a period exceeding 24 hours, the person who is in charge of the craft must ensure that gas supply to an appliance installed in the marine craft is shut off if the appliance is designed to have a continuously burning flame.
42. Duty to report certain incidents
(1) If an incident that causes or is likely to cause injury to a person or damage to property occurs, a person who is aware of the incident must immediately report it —
(a) to the relevant gas supplier and the Director; or
(b) to the Director, if —
(i) the gas installation is a mobile engine or is on or in a caravan or marine craft; or
(ii) the relevant gas supplier is not identifiable.
(2) Subregulation (1) does not apply —
(a) to a person who believes, on reasonable grounds, that the incident has already been, or is likely to have already been, reported in accordance with subregulation (1); or
(b) to a supervised gas fitter who becomes aware of the incident while doing gasfitting work and who reports the incident to a registered gas fitter who is —
(i) supervising the gasfitting work; and
(ii) authorised under Part 3A Division 1 to supervise the gasfitting work.
(3) In this regulation —
incident means an incident that involves the sudden discharge of gas or that otherwise relates to gas.
[Regulation 42 amended: SL 2023/147 r. 13.]
42A. Gas fitters to report unsafe gas installations
(1) If a gas fitter, in the course of work as a gas fitter, becomes aware of a defect that the gas fitter considers renders the gas installation, or a part of it, unsafe to use, the gas fitter must immediately notify the following of the existence and nature of the defect —
(a) the consumer for whom the gasfitting work was done;
(b) the gas supplier or (if the gas installation is a mobile engine, is on or in a caravan or marine craft or the relevant gas supplier is not identifiable) the Director.
(2) Subregulation (1) does not apply —
(a) to a gas fitter who believes, on reasonable grounds, that the defect has already been notified in accordance with subregulation (1); or
(b) to a supervised gas fitter who notifies the defect to a registered gas fitter who is —
(i) supervising the gasfitting work being done by the supervised gas fitter; and
(ii) authorised under Part 3A Division 1 to supervise the gasfitting work.
[Regulation 42A inserted: Gazette 19 Dec 2000 p. 7280; amended: SL 2023/147 r. 14.]
42B. Type A gas appliances prescribed (Act s. 4)
(1) In this regulation —
commercial means designed and manufactured for commercial use, whether or not so used;
domestic means designed and manufactured for domestic use, whether or not so used.
(2) For the purposes of the definition of Type A gas appliance in section 4 of the Act, gas appliances of the class or type specified in the Table to this regulation are prescribed.
Type A gas appliance
| 1. Domestic cooking appliances |
|---|
| 2. Domestic space heating appliances having a maximum hourly input rate of 150 MJ |
| 3. Domestic refrigerators |
| 4. Domestic outdoor barbecue grillers |
| 5. Water heaters |
| 6. Swimming pool heaters |
| 7. Commercial catering equipment — boiling tables, open and closed top |
| 8. Catalytic spaceheaters having a maximum hourly input rate of 20 MJ |
| 9. Domestic decorative gas log fires having a maximum hourly input rate of 72 MJ |
| 10. Incinerating toilets |
| 11. Cooking, lighting or heating appliances that use LPG and are designed for outdoor use |
| 12. Commercial catering equipment — salamanders and grillers |
| 13. Commercial catering equipment — solid griller plates, griddles |
| 14. Commercial catering equipment — barbecue grillers |
| 15. Commercial catering equipment — ovens |
| 16. Commercial catering equipment — boiling water units |
| 17. Commercial catering equipment — stock pots |
| 18. Commercial catering equipment — atmospheric steamers |
| 19. Commercial catering equipment — fryers |
| 20. Commercial catering equipment — food warmers, Bain‑Marie |
| 21. Commercial catering equipment — convection ovens |
| 22. Laundry dryers |
| 23. Overhead heaters |
| 24. Industrial mobile air heaters |
| 25. Indirect fired air heaters |
| 26. Air conditioning units |
| 27. Small gas engine driven appliances to which AS/NZS 5263.1.11 applies |
(3) Unless otherwise specified, a reference to an appliance in the Table to subregulation (2) is a reference to an appliance having a maximum hourly input rate of 1 000 MJ.
[Regulation 42B inserted: Gazette 30 Nov 2007 p. 5936‑7; amended: Gazette 25 Nov 2010 p. 5931; SL 2023/147 r. 15.]
Part 7 — Saving and repeal
43. Savings for repealed regulations
(1) A certificate of competency, permit or authorisation that was in force under the repealed regulations continues in force according to its tenor as if regulations 13, 14 and 15 of the repealed regulations had not been repealed.
(2) In subregulation (1) —
repealed regulations means the regulations repealed by regulation 44.
44. Repeal
The Gas Standards (Gasfitting and Consumers’ Gas Installations Regulations) 1999 are repealed.
[Schedule 1 deleted: Gazette 30 Nov 2007 p. 5937.]