Dogs Local Law 2017
5788GOVERNMENT GAZETTE, WA 1 December 2017
Start here
Get a plain-English read of 5788
Turn the raw legal text into a practical explanation grounded in Dogs Local Law 2017.
5788 GOVERNMENT GAZETTE, WA 1 December 2017 (h) in which the lighting or ventilation referred to in paragraphs (f) and (g) is obstructed or is not in good and efficient order; (i) which is not free from internal dampness; (j) of which any part of the floor is below the level of the adjoining ground; or (k) the floor of which is not fitted with an approved carpet or vinyl floor covering or other floor treatment approved by an EHO. (2) For the purposes of this clause, 2 children under the age of 10 years are counted as 1 lodger. (3) Paragraphs (a), (b) and (c) of subclause (1) do not apply to a serviced apartment. 8.18 Sleeping accommodation—short-term hostels and recreational campsites (1) A keeper of a short-term hostel or recreational campsite shall provide clear floor space of not less than— (a) 4 square metres per person in each dormitory utilising beds; and (b) 2.5 square metres per person in each dormitory utilising bunks. (2) The calculation of floor space in subclause (1) shall exclude the area occupied by any large items of furniture, such as wardrobes, but may include the area occupied by beds. (3) The minimum height of any ceiling in a short-term hostel or recreational campsite shall be 2.4 metres in any dormitory utilising beds, and 2.7 metres in any dormitory utilising bunks. (4) The minimum floor area requirements in subclause (1) will only apply if there are ventilation, separation distances, fire egress and other safety requirements in accordance with the Building Code. (5) The keeper of any short-term hostel or recreational campsite shall provide— (a) fixed outlet ventilation at a ratio of 0.15 square metres to each 10 square metres of floor area of the dormitories, and shall ensure that dormitories are provided with direct ventilation to the open air from a point within 230 millimetres of the ceiling level through a fixed open window or vents, carried as direct to the open air as is practicable; and (b) mechanical ventilation in lieu of fixed ventilation, subject to the approval of the local government. (6) The keeper of any short-term hostel or recreational campsite shall provide— (a) beds with a minimum size of— (i) in short-term hostels—800 millimetres x 1.9 metres; and (ii) in recreational campsites—750 millimetres x 1.85 metres; and (b) storage space for personal effects, including backpacks, so that cleaning operations are not hindered and access spaces are not obstructed. (7) The keeper of any short-term hostel or recreational campsite shall— (a) arrange at all times a distance of 750 millimetres between beds, and a distance of 900 millimetres between bunks; (b) ensure that, where bed or bunk heads are placed against the wall on either side of a dormitory, there is a passageway of at least 1.35 metres between each row of beds and a passageway of at least 2 metres between each row of bunks, and shall ensure that the passageway is kept clear of obstruction at all times; and (c) ensure all doors, windows and ventilators are kept free of obstruction. (8) The keeper of a short-term hostel or recreational campsite shall ensure that— (a) materials used in dormitory areas comply with AS 1530.2—1993 and AS/NZS 1530.3:1999 as follows— (i) drapes, curtains, blinds and bedcovers- a maximum Flammability Index of 6; (ii) upholstery and bedding— a maximum Spread of Flame Index of 6; and a maximum Smoke Developed Index of 5; and (iii) floor coverings— a maximum Spread of Flame Index of 7; and a maximum Smoke Developed Index of 5; (b) fire retardant coatings used to make a material comply with the indices set out in subclause (8)(a) must be— (i) certified by the manufacturer as approved for use with the fabric to achieve the required indices; (ii) certified by the manufacturer to retain its fire retardative effect after a minimum of 5 commercial dry cleaning or laundering operations carried out in accordance with AS 2001.5.4—2005, Procedure 7A, using ECE reference detergent; and (iii) certified by the applicator as having been carried out in accordance with the manufacturer’s specification of the product; (c) emergency lighting is provided in accordance with the Building Code; (d) a lodger or other person does not smoke in any dormitory, kitchen, dining room or other enclosed public place within a short-term hostel or recreational campsite; and (e) all mattresses in a short-term hostel or recreational campsite are fitted with a mattress protector.