E3.6 Passenger lifts
In an accessible building, every passenger lift must:
(a) be one of the types identified in Table E3.6 (a), subject to the limitations on use specified in the table; and
(b) have accessible features in accordance with Table E3.6 (b); and
(c) not rely on a constant pressure device for its operation if the lift car is fully enclosed.
Table E3.6 (a) Limitations on use of types of passenger lifts
| Lift type | Limitations on use |
|---|---|
| Electric passenger lift | No limitation. |
| Electrohydraulic passenger lift | No limitation. |
| Inclined lift | No limitation. |
| Low-rise platform lift | Must not travel more than 1 m. |
| Low-rise, low-speed constant pressure lift | Must not:(a) for an enclosed type, travel more than 4 m; or(b) for an unenclosed type, travel more than 2 m; or(c) be used in high traffic public use areas in buildings such as a theatre, cinema, auditorium, transport interchange, shopping complex or the like. |
| Small-sized, low-speed automatic lift | Must not travel more than 12 m. |
| Stairway platform lift | Must not:(a) be used to serve a space in a building accommodating more than 100 persons calculated according to clause D1.13 of the BCA; or(b) be used in a high traffic public use area such as a theatre, cinema, auditorium, transport interchange, shopping centre or the like; or(c) be used where it is possible to install another type of passenger lift; or(d) connect more than 2 storeys; or(e) where more than 1 stairway lift is installed, serve more than 2 consecutive storeys; or(f) when in the folded position, encroach on the minimum width of a stairway required by clause D1.6 of the BCA. |
Table E3.6 (b) Application of features to passenger lifts
| Feature | Application |
|---|---|
| Hand rail complying with the provisions for a mandatory handrail in AS 1735.12 | All lifts except:(a) a stairway platform lift; and(b) a low-rise platform lift. |
| Lift floor dimension of not less than 1,400 mm wide x 1,600 mm deep | All lifts which travel more than 12 m. |