A fixed or moveable ramp must:
(a) have a slip‑resistant surface; and
(b) have a maximum gradient of 1:14; and
(c) have handrails complying with the requirements for ramps in AS 1428.1, installed on both sides of the ramp; and
(d) have kerbs in accordance with the requirements for ramps in AS 1428.1; and
(e) extend to a depth of not less than 900 mm and not more than 1 100 mm below the stationary water level; and
(f) have landings in accordance with the requirements for ramps in AS 1428.1, with a landing located at the bottom and top of each ramp and a landing must be located at a level between 900 mm and 1 100 mm below the stationary water level.