In a building required to be accessible:
(a) every ramp and stairway, except for ramps and stairways in areas exempted by clause D3.4, must comply with:
(i) for a ramp, except a fire‑isolated ramp, clause 7 of AS 1428.1; and
(ii) for a stairway, except a fire‑isolated stairway, clause 8 of AS 1428.1; and
(iii) for a fire‑isolated stairway, clause 8.1(f) and (g) of AS 1428.1; and
(b) every passenger lift must comply with clause E3.6; and
(c) accessways must have:
(i) passing spaces complying with AS 1428.1 at maximum 20 m intervals on those parts of an accessway where a direct line of sight is not available; and
(ii) turning spaces complying with AS 1428.1:
(A) within 2 m of the end of accessways where it is not possible to continue travelling along the accessway; and
(B) at maximum 20 m intervals along the accessway; and
(d) an intersection of accessways satisfies the spatial requirements for a passing and turning space; and
(e) a passing space may serve as a turning space; and
(f) a ramp complying with AS 1428.1 or a passenger lift need not be provided to serve a storey or level other than the entrance storey in a Class 5, 6, 7b or 8 building‑
(i) containing not more than 3 storeys; and
(ii) with a floor area for each storey, excluding the entrance storey, of not more than 200 m2.