Australia New Zealand Food Standards Code - Standard 3.2.3 - Food Premises and Equipment
Division 3Floors, walls and ceilings
Start here
Get a plain-English read of Division 3
Turn the raw legal text into a practical explanation grounded in Australia New Zealand Food Standards Code - Standard 3.2.3 - Food Premises and Equipment.
Division 3 – Floors, walls and ceilings
9 Application
The requirements for floors, walls and ceilings specified in this Division apply to the floors, walls and ceilings of all areas used for food handling, cleaning, sanitising and personal hygiene except the following areas –
(a) dining areas;
(b) drinking areas; and
(c) other areas to which members of the public usually have access.
10 Floors
(1) Floors must be designed and constructed in a way that is appropriate for the activities conducted on the food premises.
(2) Subject to subclause (3), floors must –
(a) be able to be effectively cleaned;
(b) be unable to absorb grease, food particles or water;
(c) be laid so that there is no ponding of water; and
(d) to the extent that is practicable, be unable to provide harbourage for pests.
(3) The following floors do not have to comply with subclause (2) –
(a) floors of temporary food premises, including ground surfaces, that are unlikely to pose any risk of contamination of food handled at the food premises; and
(b) floors of food premises that are unlikely to pose any risk of contamination of food handled at the food premises provided the food business has obtained the approval in writing of the appropriate enforcement agency for their use.
11 Walls and ceilings
(1) Walls and ceilings must be designed and constructed in a way that is appropriate for the activities conducted on the food premises.
(2) Walls and ceilings must be provided where they are necessary to protect food from contamination.
(3) Walls and ceilings provided in accordance with subclause (2) must be –
(a) sealed to prevent the entry of dirt, dust and pests;
(b) unable to absorb grease, food particles or water; and
(c) able to be easily and effectively cleaned.
(4) Walls and ceilings must –
(a) be able to be effectively cleaned; and
(b) to the extent that is practicable, be unable to provide harbourage for pests.