COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 107 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Image unavailable in extracted text Radio Communication and Navigation Equipment
AD/RAD/13
Amdt 1
VHF Transceiver Circuit Protection - Modification 10/65
Applicability: Rexair VTR-5 series Transceivers installed with interwiring looms supplied by Rex Aviation.
Requirement: Modify interwiring or equipment to provide adequate circuit protection for all wiring between the control unit and the transceiver.
Note: This requirement can be met by incorporating Rex Aviation Design Change No. 7 which provides a 5 amp fuse in the control unit.