AD/PA-31/85 - Cigar Lighters - Disconnection
1AD/PA-31/85 - Cigar Lighters - Disconnection
Start here
Get a plain-English read of 1
Turn the raw legal text into a practical explanation grounded in AD/PA-31/85 - Cigar Lighters - Disconnection.
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Image unavailable in extracted text
Piper PA-31 Series Aeroplanes
AD/PA-31/85 Cigar Lighters - Disconnection 11/79
Applicability: All models PA-31 and PA-31-325 with S/Nos. 31-7712074 to 31-7912098 and PA- 31-350 with S/Nos. 31-7752096 to 31-7952197 equipped with three 12 Volt cigar lighters powered through a triplet of voltage dropping resistors.
Requirement: 1. For models PA-31 and PA-31-325 S/Nos 31-7712074 to 31-7912000, and PA-31- 350 S/Nos. 31-7752096 to 31-7952000; disconnect wire CIG-1 from the 7 amp circuit breaker located at the voltage dropping resistor assembly under the instrument panel or disconnect wire CIG-1A from the 15 Amp “Heater and Cigar Lighter” circuit breaker located on the pilot’s circuit breaker panel.
- For models PA-31 and PA-31-325 S/Nos. 31-7912001 to 31-7912098 and PA-31-
350 S/Nos. 31-7952001 to 31-7952197 except 31-7952191, 31-7952193, 31-
7952195; disconnect wire CIG-1 from the 7 Amp “Lighter” circuit breaker located on the pilot’s circuit breaker panel.
- After disconnection, protect the wire by insulating its disconnected end and fold the wire end back against itself or the bundle in which it is routed and secure it.
Note: FAA AD 79-20-07 Amdt. 39-3573 refers.
Compliance: Within the next 100 hours time in service after 30 November 1979.
Background: During flight voltage dropping resistors have been burning and causing smoke in the cockpit.