BAe Systems (Operations) Jetstream 4100 Series Aeroplanes
BAe Systems (Operations) Jetstream 4100 Series Aeroplanes
| AD/J4100/18 | Aft Fuselage Frames | 4/2008 DM |
|---|
| Applicability: | All Model Jetstream Series 4100 aircraft. |
|---|---|
| Requirement: | Action in accordance with BAE Systems Mandatory Service Bulletin J41-53-051 Revision 1, or later CAA/EASA approved revision.Note: UK CAA AD 003-01-2002 refers. |
| Compliance: | Unless the initial inspection is already accomplished, within 30 days after20 February 2008. Thereafter at intervals not to exceed 2 years. |
| This Airworthiness Directive becomes effective on 20 February 2008. | |
| Background: | Corrosion has been detected along the aft fuselage frames. The corrosion occurs on frame areas below floor panel level in the vicinity of the toilet, galley and rear baggage door due to the ingress of water / liquid spillage. |
View image in the official source
David Villiers
Delegate of the Civil Aviation Safety Authority
15 February 2008