Sourced from the Federal Register of Legislation (legislation.gov.au), CC BY 4.0.
AIRWORTHINESS DIRECTIVE AIRWORTHINESS DIRECTIVE
AIRWORTHINESS DIRECTIVE
For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.1 (1) of CAR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
AD/HU 369/103 Turbine Outlet Temperature AD/HU 369/103 Turbine Outlet Temperature Wire Harness 7/2000
AD/HU 369/103 Turbine Outlet Temperature Wire Harness 7/2000
DM
Applicability: Model 369D, 369E and 500N series helicopters with analogue/digital turbine outlet temperature (TOT) indicator, part number (P/N) 369D24513-1, installed; and Model 600N helicopters, with analogue/digital TOT indicator, P/N 9A3420 installed.
Requirement: 1. For Model 369E, 369D, and 500N helicopters -
Test the TOT indicating system to verify correct calibration in accordance with the Accomplishment Instructions, Part I, of MD Helicopters, Inc. (MDHI) Service Bulletin SB369D-199, SB369E-093, SB500N-019, dated 11 January 2000, as applicable.
b. If, during any test required by Requirement 1.a., the TOT indicator readings for the tester setting temperatures in Table 1, Part I, of the SB are not within the indicator reading range, perform the actions specified in the Accomplishment Instructions, Part I, paragraph (6)(b) of the applicable SB.
2. For Model 600N helicopters \-
Test the TOT indicating system, including the electronic control unit (ECU) TOT sensing system, to verify correct calibration in accordance with the Accomplishment Instructions, Part I, of MDHI SB600N-026, dated 11 January 2000.
b. If, during any calibration test required by Requirement 2.a., the TOT indicator readings for the tester setting temperatures in Table 1, Part I, of the SB are not within the indicator reading range, perform the actions specified in the Accomplishment Instructions, Part I, paragraph (7)(b) of the SB.
c. If, during any test required by Requirement 2.a., the Full Authority Digital Electronic Control (FADEC) maintenance lap-top terminal does not indicate ECU TOT within ± 5 degrees Celsius of the tester setting in Table 1, Part I, of the SB, perform the actions specified in the Accomplishment Instructions, Part III, of the SB.