AD/FA-200/24 - Elevator Torque Tube Corrosion
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
View image in the official source Fuji FA-200 Series Aeroplanes
AD/FA-200/24 Elevator Torque Tube Corrosion 11/89
Applicability: All FA 200 S/No. 12 and subsequent. Requirement: Action in accordance FHI S.B. 200-009.
Compliance: Within 100 hours time in service after 2 November 1989, or at the next scheduled inspection for issue of Maintenance Release after 2 November 1989 whichever occurs later, and thereafter at intervals not exceeding 5 years.
Background: Corrosion has been found inside elevator torque tubes to a depth that necessitated replacement. Undetected this could lead to tube failure.