| AD/DO 328/9 | DC Power Unit 1VE Electrical Connections | 1/2006 |
|---|
| Applicability: | Model 328-100 aeroplanes with serial numbers 3005 to 3086 inclusive. |
|---|---|
| Requirement: | 1. If not previously accomplished, carry out the following actions in accordance with the Accomplishment Instructions of Dornier Service BulletinsSB-328-24-018, dated 5 August 1997: |
| a. Perform a one time visual inspection of the electrical connection studs of the 1VE DC Power Unit to ensure correct installation of the terminals and spring washers. | |
| b. Perform a one time torque check of the electrical connection studs of the 1VE DC Power Unit. | |
| 2. Correct any deficiencies found during the Requirement 1 inspection and torque check. | |
| Note: LBA AD 97-322 refers. | |
| Compliance: | For Requirement 1 - Within 30 days after the effective date of this Directive. |
| For Requirement 2 - Before further flight after completing Requirement 1. | |
| This Airworthiness Directive becomes effective on 19 January 2006. | |
| Background: | The German Luftfahrt-Bundesamt (LBA) has received reports of overheating at the electrical connection studs of the 1VE unit due to wrongly installed terminals and spring washers together with incorrect torque of the stud nuts.This Directive requires both an inspection and torque check of the electrical connection studs and, if necessary, rectification of any anomalies. |
Image unavailable in extracted text
James Coyne
Delegate of the Civil Aviation Safety Authority
29 November 2005