Dornier 328 Series Aeroplanes
Dornier 328 Series Aeroplanes
| AD/DO 328/7 | Relays 32HB and 36HB | 1/2006 |
|---|
| Applicability: | Model 328-100 aeroplanes with serial numbers 3005 to 3089 inclusive. |
|---|---|
| Requirement: | If not previously accomplished, replace relays 32HB and 36HB part number (P/N) DON405M520U5NL with new relays 2504MY1 in accordance with the Accomplishment Instructions of Dornier Service Bulletins SB-328-21-218, dated 2 July 1997. |
| Note: LBA AD 97-323 refers. | |
| Compliance: | Within 30 days after the effective date of this Directive. |
| This Airworthiness Directive becomes effective on 19 January 2006. | |
| Background: | The existing relay, when exposed to high electrical loads, overheats beyond its permissible operating range. |
View image in the official source
James Coyne
Delegate of the Civil Aviation Safety Authority
29 November 2005