Dornier 328 Series Aeroplanes
Dornier 328 Series Aeroplanes
| AD/DO 328/60 | Flight Control - Potentiometer Levers | 6/2006 |
|---|
| Applicability: | Dornier 328-100 aeroplanes, serial numbers 3005 through 3119 inclusive. |
|---|---|
| Requirement: | Unless previously accomplished, carry out an inspection of all the positions where the levers are used in the fuselage under floor cockpit area in accordance with Dornier 328 Service Bulletin (SB) No. SB-328-27-359 dated 29 March 2001.Note: LBA AD 2001-167/2 dated 28 June 2001 refers. |
| Compliance: | Within 30 days after the effective date of this AD. |
| This Airworthiness Directive becomes effective on 8 June 2006. | |
| Background: | Due to a build up of tolerances in the flight control potentiometer lever design it is possible for one of the built in safety lock functions to be rendered ineffective. |
View image in the official source
James Coyne
Delegate of the Civil Aviation Safety Authority
28 April 2006