AD/CHA/20 - Alternator - Field Cable Protection
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
View image in the official source American Champion (Aeronca, Bellanca) Series Aeroplanes
AD/CHA/20 Alternator - Field Cable Protection 6/78
Applicability: All models fitted with an Alternator System.
Requirement: Install a 5 AMP circuit protective device (i.e. in line fuse or circuit breaker) in the field cable as close as practical to the master switch.
Compliance: Within 100 hours time in service after 30 June 1978.