CTHIn ForceLegislation
AD/CESSNA 180/90 - Fuel Line Chafing
© 2026 Zoe. All rights reserved.
Zoe is a legal information platform. Always consult the Federal Register of Legislation for authoritative text.
AD/CESSNA 180/90 - Fuel Line Chafing
Start here
Turn the raw legal text into a practical explanation grounded in AD/CESSNA 180/90 - Fuel Line Chafing.
| AD/CESSNA 180/90 | Fuel Line Chafing | 6/2007 DM |
|---|
| Applicability: | Models 182H, 182J, 182K, 182L, 182M, 182N, 182P, 182Q and 182R aeroplanes, all serial numbers, that: |
|---|---|
| a. Have Air Plains Services Corporation United States Federal Aviation Administration (FAA) Supplemental Type Certificate (STC) SA00152WI installed, and | |
| b. Have a ground power receptacle mounted on the firewall (forward ground power receptacle). | |
| Requirement: | 1. Remove power to the ground power electrical cable by accomplishing either of the following in accordance with Air Plains Services Corporation Mandatory Service Bulletin (SB) APS-07-01-01, dated 5 March 2007: |
| a. Disconnect the electrical cable at the forward ground power relay and the starter relay, or | |
| b. Remove the electrical cable between the forward ground power relay and the starter relay. | |
| 2. Fabricate and install a placard as close as possible to the forward ground power receptacle that incorporates the following words (using at least 3mm [0.125 inch] red letters on a white background and a red border): | |
| “Ground Power Receptacle is Inoperative” | |
| 3. Reposition the fuel strainer cable in accordance with SB APS-07-01-01. | |
| 4. Visually inspect the fuel line from the auxiliary electric fuel pump to the engine-driven fuel pump for chafing. | |
| 5. If chafing at or beyond the limits defined in the SB APS-07-01-01, is found in the Requirement 4 inspection, replace the fuel line between the auxiliary electric fuel pump and the engine-driven fuel pump with a new hose part number AE3663161G0190 (or FAA-approved equivalent) and remove the ground power electrical cable per Requirement 1.b. | |
| 6. Adjust the position of the fuel line fitting at the engine-driven fuel pump in accordance with SB APS-07-01-01. | |
| Later revisions of the above SB, approved by the FAA as an Alternate Method of Compliance (AMOC) to FAA AD 2007-09-01, are considered acceptable for compliance with the equivalent Requirements of this Directive. | |
| Note: FAA AD 2007-09-01 Amdt 39-15031 refers. | |
| Compliance: | For Requirement 1 - Before 12 May 2007. |
| For Requirement 2 - Before further flight after the power to the ground power receptacle is removed in accordance with Requirement 1. | |
| For Requirements 3 and 4 - Before 12 May 2007. | |
| For Requirement 5 - Before further flight if any chafing is found during the Requirement 4 inspection. | |
| For Requirement 6 - Before 12 May 2007. | |
| This Airworthiness Directive becomes effective on 27 April 2007. | |
| Background: | The FAA has received a report of a Cessna Model 182Q aeroplane with Air Plains Services Corporation STC SA00152WI installed that had an in-flight and post-landing fire. The preliminary finding, per the United States National Transportation Safety Board (NTSB), is that the electrical cable between the forward ground power relay and the starter relay chafed on either the fuel strainer control or on the fuel line between the auxiliary electric fuel pump and the engine-driven fuel pump. The cable shorted, welded the fuel strainer control cable to the firewall, and burned the fuel line between the auxiliary electric fuel pump and the engine-driven fuel pump. |
| This Directive requires the disconnection or removal of the electrical cable between the forward ground power relay and the starter relay, the installation of a placard, the inspection of the fuel line between the auxiliary electric fuel pump and the engine-driven fuel pump for chafing and, if necessary, the replacement of the fuel line if chafing is found. The Directive is issued to detect and correct interference between the ground power electrical cable, the fuel strainer cable and the fuel line between the auxiliary electric fuel pump and the engine-driven fuel pump. This condition could lead to a fire in the engine compartment. |
Image unavailable in extracted text
David Punshon
Delegate of the Civil Aviation Safety Authority
23 April 2007