AD/BAL/10 - Wire Rope Vent and Rip Lines
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
View image in the official source Hot Air Balloons
AD/BAL/10 Wire Rope Vent and Rip Lines 7/90
Applicability: All hot air balloons.
Requirement: 1. Gain access to the lower section of the rip and vent control lines.
2. Examine the lower 7 metres for evidence of wire rope.
3. If wire rope is found replace affected lines with same diameter kevlar core polyester covered line or other suitable non-conductive alternative.
Note: Kavanagh Balloons Engineering Order KB / 90 / 03 provides a suitable means of compliance.
Compliance: Prior to 31 December 1990.
Background: To reduce potential electrical shock hazards to the pilot and passengers, all metal control lines are replaced with non-conductive control lines.