| AD/B767/216 | Frequency Converters - Medicaland Galley Utility Outlets | 2/2006 |
|---|
| Applicability: | Model 767-300 series aeroplanes, identified in Boeing Service Bulletin (SB) 767-25-0334, Revision 1, dated 19 June 2003. |
|---|---|
| Requirement: | 1. If not previously accomplished, either: |
| a. Replace the frequency converters used to supply power for medical and galley utility outlets with modified frequency converters in accordance with the Accomplishment Instructions of SB 767-25-0334 Revision 1. | |
| or | |
| b. Remove and deactivate the frequency converters used to supply power for medical and galley utility outlets, and cap and stow the frequency converter wire bundles, in accordance with paragraphs B.1. through B.6. of the Accomplishment Instructions of SB 767-25-0334 Revision 1. | |
| Actions accomplished before the effective date of this Directive in accordance with SB 767-25-0334, dated 7 November 2002, are acceptable for compliance with Requirement 1. | |
| Later revisions of the above SB, approved by the United States Federal Aviation Administration (FAA) as an Alternate Method of Compliance (AMOC) to FAA AD 2005-24-04, are considered acceptable for compliance with the equivalent Requirements of this Directive. | |
| 2. Frequency converters that have not been modified in accordance with the Accomplishment Instructions of the service bulletin may not be installed as a replacement spare. | |
| Note: FAA AD 2005-24-04 Amdt 39-14384 refers. | |
| Compliance: | For Requirement 1 - Within 18 months after the effective date of this Directive. |
| For Requirement 2 - As of the effective date of this Directive. | |
| This Airworthiness Directive becomes effective on 16 February 2006. |
| Background: | The FAA has received a report indicating that a hard short circuit condition between the output of certain frequency converters and their downstream circuit breakers will produce a continuous output current that could cause the undersized output wiring to overheat when the frequency converters fail to shut off. |
|---|