What it does
Airworthiness Directive AD/B767/207, issued by the Civil Aviation Safety Authority (CASA) and effective 17 March 2005, mandates specific maintenance actions on certain Boeing 767‑300 series aeroplanes to address an identified unsafe condition. The directive focuses on the Auxiliary Power Unit (APU) and engine fire shutoff switches. According to the background, Boeing determined that humidified air from certain Lucas (TRW Systemes Aeronautiques) humidifiers caused mineral build‑up on the switch contacts, leading to failures that could prevent the switches from discharging fire suppressant. An uncontrolled fire could then spread to the strut, wing, or aft body.
The directive imposes three core operations. First, a repetitive functional test of the APU and engine fire shutoff switches must be carried out in accordance with Boeing Alert Service Bulletin (ASB) 767‑26A0127 dated 17 July 2003. This test must be performed initially within either 18 months since the date of issue of the original Certificate of Airworthiness or original Export Certificate of Airworthiness, or within 90 days after the effective date of the directive, whichever occurs later. Thereafter the test must be repeated at intervals not exceeding 18 months. Second, if any switch fails a functional test, it must be replaced with a new or serviceable switch before further flight. Third, all APU and engine fire shutoff switches that have not previously been replaced after a failed test must be replaced within 18 months of the directive’s effective date, and thereafter at intervals not exceeding 36 months.
The directive provides an optional terminating action for the repetitive tests and replacements. If the Lucas humidifier (part numbers M01AA0101, M01AB0101, M01AB0102, or M01AB0103) is deactivated, the repetitive tests and switch replacements may cease. However, if the humidifier is deactivated, all APU and engine fire shutoff switches must be replaced with new or serviceable switches before further flight. If the humidifier is later reactivated, the operator must re‑commence the functional tests within 18 months and replace all switches not previously replaced within 36 months, with ongoing repetitions thereafter. On its face, the directive offers a regulatory trade‑off: operators may choose to eliminate the repetitive burden by deactivating the humidifier, but that choice comes with a one‑time switch replacement and the loss of the humidifier’s functionality. The directive references FAA AD 2005‑01‑13 (Amdt 39‑13938), indicating alignment with a corresponding US airworthiness directive, which may affect operators of aircraft on the Australian register that also operate under FAA oversight.