AD/B747/77 - APU Fire Detection
1AD/B747/77 - APU Fire Detection
Start here
Get a plain-English read of 1
Turn the raw legal text into a practical explanation grounded in AD/B747/77 - APU Fire Detection.
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Image unavailable in extracted text Boeing 747 Series Aeroplanes
AD/B747/77 APU Fire Detection 5/90
Applicability: All model Boeing 747-400 series aeroplanes as listed in Boeing SB 747-26-2135 Revision 1, or later revision.
Requirement: Modify the APU electrical power circuitry in accordance with Boeing SB 747-26- 2135 Revision 1 or later revision.
Compliance: Prior to 17 August 1990.
Background: In the current configuration if the main battery switch is turned off whilst the APU is operating, power to the APU fire detection system is removed. The APU goes through a 60 second cool down cycle with the fire detection system inoperative.
Compliance with this AD is required to correct this unacceptable condition.