AD/B737/168 - Main Wheel Well Junction Box Electrical Wire Chafing
1AD/B737/168 - Main Wheel Well Junction Box Electrical Wire Chafing
Start here
Get a plain-English read of 1
Turn the raw legal text into a practical explanation grounded in AD/B737/168 - Main Wheel Well Junction Box Electrical Wire Chafing.
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
Image unavailable in extracted text
AIRWORTHINESS DIRECTIVE
For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.1 (1) of CAR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
Image unavailable in extracted text
Boeing 737 Series Aeroplanes
AD/B737/168 Main Wheel Well Junction Box Electrical Wire Chafing
12/2001
Applicability: All Model 737-100, -200, -300, -400, and -500 series aeroplanes; and Model 737-600,
-700, -800, and -900 series aeroplanes, line numbers 1 through 706 inclusive.
Requirement: 1. Perform a detailed visual inspection of the wire bundles in the four junction boxes formed by electrical disconnect brackets on the left and right sides of the main wheel wells to detect damage or chafing, as specified in Boeing Service Letter (SL) 737-SL-24-111-B, dated 16 January 2001.
Note 1: For the purposes of this Directive, a detailed visual inspection is defined as: “An intensive visual examination of a specific structural area, system, installation, or assembly to detect damage, failure, or irregularity. Available lighting is normally supplemented with a direct source of good lighting at intensity deemed appropriate by the inspector. Inspection aids such as mirror, magnifying lenses, etc., may be used. Surface cleaning and elaborate access procedures may be required.”
2. If chafing is not detected during the Requirement 1 inspection, protect the wire bundles from chafing against the cover plate of the junction box in accordance with SL 737-SL-24-111-B.
3. If any chafing is detected during the Requirement 1 inspection, repair the wiring and protect the wire bundles from chafing against the cover plate of the junction box in accordance with SL 737-SL-24-111-B.