AIRWORTHINESS DIRECTIVE AIRWORTHINESS DIRECTIVE
AIRWORTHINESS DIRECTIVE
For the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.1 (1) of CAR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.
Boeing 727 Series Aeroplanes
AD/B727/181 Wire Bundle Chafing 11/2002 AD/B727/181 Wire Bundle Chafing 11/2002
AD/B727/181 Wire Bundle Chafing 11/2002
Applicability: Model 727 series aeroplanes.
Requirement: 1. Carry out a general visual inspection to detect discrepancies (including inadequate clearance between the wire bundles and hydraulic tubing and/or structure, missing clamps, chafing, fire damage to structure or damage to wire bundles) of the wire bundles and hydraulic tubing in the aft stairwell area, in accordance with the Work Instructions of Boeing Alert Service Bulletin (ASB) 727-29A0068, dated 30 May 2002. If discrepancies are not found, further action is not required by this Directive.
Note 1: For the purposes of this Directive, a general visual inspection is defined as: "A visual examination of an interior or exterior area, installation, or assembly to detect obvious damage, failure, or irregularity. This level of inspection is made from within touching distance unless otherwise specified. A mirror may be necessary to enhance visual access to all exposed surfaces in the inspection area. This level of inspection is made under normally available lighting conditions such as daylight, hangar lighting, torch or droplight and may require removal or opening of access panels or doors. Stands, ladders or platforms may be required to gain proximity to the area being checked."
- If any discrepancy is found during the Requirement 1 inspection, rectify the discrepancy (includes repositioning of the wire bundles and clamps to ensure a minimum clearance of 0.25 inch between the wire bundles and hydraulic tubing and/or structure and installing clamps; repairing or replacing any damaged wiring and tubing; if evidence of fire damage, inspecting adjacent structural area for damage, and repairing any damage), per Figure 1 of the ASB.