AD/AMD 50/18 - Frame 25 Water Drainage
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-generator: Aspose.Words for .NET 22.10.0
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
View image in the official source AMD Falcon 50 and 900 Series Aeroplanes
AD/AMD 50/18 Frame 25 Water Drainage 13/99
Applicability: MF 900 S/n 1 to 177 and F900 EX S/n 1 to 41.
Requirement: Modify in accordance with Dassault Aviation SB MF900-232 or F900EX-093 as appropriate.
Note: DGAC AD 1999-446-028(B) refers.
Compliance: Before 30 June 2000.
This Airworthiness Directive becomes effective on 30 December 1999.
Background: Manufacturer flight testing revealed that water does not drain properly through the Frame 25 filter and if it froze could lead to jamming of the flight controls.