AD/A320/95 - Avionics Rack Protection
meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-description: CASA Airworthiness Directive meta-generator: Aspose.Words for .NET 22.10.0 meta-keywords: Issue 9/1998,Aircraft above 5700 kg,Airbus Industrie A319, A320 and A321 Series Aeroplanes,Avionics Rack Protection,95 title: Airworthiness Directive - AD/A320/95 - Avionics Rack Protection
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
View image in the official source Airbus Industrie A319, A320 and A321 Series Aeroplanes
AD/A320/95 Avionics Rack Protection 9/98
Applicability: All models A320, A321, and A319 series aircraft, without Airbus Industrie Modification 25995 or Service Bulletin A320-25-1186 incorporated.
Requirement: Action in accordance with the instructions of Airbus Industrie Service Bulletin A320-25-1186.
Note: DGAC AD 98-178-115(B) refers.
Compliance: Unless already accomplished, before 16 May 2000.
This airworthiness directive becomes effective on 13 August 1998.
Background: The manufacturer received several reports of water ingress into the avionics bay. In some cases this has led to damage of computer electrical connectors. An extension of the existing water protection devices is required.