meta-content-style-type: text/css meta-content-type: application/xhtml+xml; charset=utf-8 meta-description: CASA Airworthiness Directive meta-generator: Aspose.Words for .NET 22.10.0 meta-keywords: Issue 4/1996,Aircraft above 5700 kg,Airbus Industrie A319, A320 and A321 Series Aeroplanes,Lavatories Smoke Detection,63 title: Airworthiness Directive - AD/A320/63 - Lavatories Smoke Detection
?xml version="1.0" encoding="utf-8" standalone="no"?>
COMMONWEALTH OF AUSTRALIA (Civil Aviation Regulations 1998), PART 39 - 105 CIVIL AVIATION SAFETY AUTHORITY
SCHEDULE OF AIRWORTHINESS DIRECTIVES
Image unavailable in extracted text Airbus Industrie A319, A320 and A321 Series Aeroplanes
AD/A320/63 Lavatories Smoke Detection 4/96
Applicability: All models without Modifications 22561 or 24548 embodied; or Airbus Industrie SBs A320-26-1017 or A320-26-1037 incorporated.
Requirement: Action in accordance with Airbus Industrie SB A320-26-1037.
Note: DGAC ADs 94-168-058(B)R1 and 96-007-073(B) refer.
Compliance: Unless already accomplished, within 500 hours’ time in service after 28 March 1996. Background: This Directive provides terminating action for the inspection required by Airbus
A320/AOT 26-12 which required an inspection of the lavatory air extraction grill to
prevent degradation of the smoke detecting system.