The Body Corporate for The Arbour on Grey - South (respondent)
Section 88 of Schedule 4 of the South Bank Corporation Act 1989 (SBCA)
BY-LAW specifying minimum sound isolation impact control for hard flooring - whether should not have been made
SBCA, s 88 of Schedule 4
41.1 An Occupier must not install or cause to be installed or place in or upon any part of the lot hard flooring such as timber, tiles, marble or any similar material unless the Occupier has first obtained the written approval of the Committee, which may be given with or without conditions.
41.2 Any approval provided under this by-law is conditional upon the Occupier demonstrating that the flooring proposed to be installed will:
(a) achieve an acoustic rating acceptable for a five-star apartment building as published by the Association of Australian Acoustical Consultants from time to time;
(b) achieve an acoustic rating acceptable for a six-star apartment building as published by the Association of Australian Acoustical Consultants if the flooring will be installed directly above a bedroom beneath the lot; and
(c) not interfere with any ceiling acoustic treatment.
41.3 An Occupier must comply with any conditions imposed by the Committee when granting its consent, including any conditions which are imposed by the Committee, to prevent any noise arising in any way out of the installation or use of the flooring from being transmitted from the lot to another lot.
41.4 The granting of any approval by the Committee does not in any way relieve an Occupier of its responsibility under any other by-law.
41.5 In the event that an Occupier fails to comply with the terms of this by-law, then the Occupier must, at its own expense, remove the flooring from the lot upon receiving written notice from the Committee to do so.
7P1 - Sound transmission through floors - 2019: FP5.1
A floor separating sole-occupancy units or a sole-occupancy unit from a plant room, lift shaft,
stairway, public corridor, public lobby, or the like, or parts of a different classification, must
minimise the transmission of airborne and impact generated sound such that the separating
floor, including the effect of services and their penetrations, has -
a. a weighted standardised level difference with spectrum adaptation term (DnT,w + Ctr) not
b. a weighted standardised impact sound pressure level (LnT,w) not more than 62 for impact
Some designs require floors to be sound-rated to meet the NCC provisions. Carpet may only be one option to meet the impact rating on floors. Alternative hard-floor systems also need to be considered. This is the case whether the hard floor covering is installed as part of the initial fit out or as part of a future occupant upgrade. The design for both the hard floor covering and carpet options should allow for:
a) The slab is only 150mm thick on all the floor areas of each unit. > > b) Arbour on Grey - North (Stage 1) are in the process of changing their by-laws to match Souths due to the continual noise complaints when carpets are replaced with hard flooring. > > c) The unit above 2322 (2413) (lot 95) is a lock up unit and has been for at least the last 5 years. Nobody resides in that unit. This would be giving the Slingers a false sense of the noise transfer between floors as there is nobody above them for them to hear any noise. > > d) It was around 2018 that owners voted on restoring the hard flooring guidelines back to the original standard put out by Mirvac when they built the building in 2002. This was because there were too many complaints regarding noise transfer after hard flooring was put down. One complaint was from the owner who lived below him when he put hard flooring down in about 2012, but was rejected due to the length of time it was down and no complaints had been made until 2016. There have been around 5 units that have installed hard flooring since the amended by-laws came into effect and all have met the required standards. > > e) The Slingers have not had any flooring down since around December last year and the noise has been very bad at times, which he knows is because there is no flooring. But he believes if they put the hard flooring down that they want, it may force him to reconsider living there after 15 years. > > f) As a committee member, he has abstained from voting on the Slinger's application because of his conflict of interest.
a) It is unclear on what basis the applicants seek the orders. > > b) It was within the power of the body corporate to make by-laws 41.2(a) and (b). > > c) By-laws 41.2(a) and (b) are valid. > > d) It has a statutory obligation to enforce the by-laws. > > e) There is no requirement for the by-laws of a body corporate governed by the BUGTA to be reasonable to the standard imposed by the Body Corporate and Community Management Act 1997 (BCCM Act). > > f) In any event, the body corporate considers they are reasonable and proportionate, having regard to: > > 1. The design intent and construction of the building/s in the plan having a high standard of acoustic performance; > 2. The evidence demonstrating that the standard prescribed in the by-laws are both consistent with that intent and achievable; and > 3. The interests of all owners within the plan.
No by-laws or any amendment of or addition to a by-law shall be capable of operating to prohibit or restrict the devolution of a leasehold estate in a lot, or a transfer, sublease, mortgage or other dealing with a leasehold estate in a lot, or to destroy or modify any easement, service right or service obligation implied or created by this Act.
Concerns were raised that there had been insufficient discussion and consultation with the wider group of owners some of which were considered too prescriptive, such as those by-laws requiring an application to undertake a certain action. The Committee advised that the proposed amendments to the by-laws was the first such review undertaken since construction and amendments could be made in future years and recommended that future reviews occur at least every five years.
[69] There is no express requirement, in the BUGTA, that a by-law not be oppressive or unreasonable. However, the parties agree that, at common law, as with delegated legislation, a by-law (even one forming part of a statutory contract) must be the result of a genuine and real exercise of the power to make it: the power must not have been exercised for a purpose not related (that is, ulterior) to the purpose for which it was conferred on the body corporate. It is in that sense that a by-law must be reasonable.
[70] A by-law made under such a power must be within the scope of what parliament intended when enacting the statute that gave the power to a subordinate body (in this case, the body corporate). It must not be so capricious and irrational that no reasonable person exercising the power could have devised it. It must be reasonably proportionate to the end to be achieved under the legislation. It is not enough that a reviewing decision maker may think the by-law to be inexpedient or misguided. It must be so lacking in reasonable proportionality as not to be a real exercise of the power. [12]
a) The design intent and construction of the building/s in the plan having a high standard of acoustic performance; > > b) The evidence demonstrating that the standard prescribed in the by-laws are both consistent with that intent and achievable; and > > c) The interests of all owners within the plan.
Where tiles or timber flooring is laid by the purchaser in lieu of carpet, adherence to strict acoustic standards is necessary.
Hard floor surfaces must not be laid over bedrooms in apartments below, as satisfactory acoustic isolation is unachievable without an acoustic ceiling in the bedroom below together with the following acoustic floor treatment.
An acoustic screed is to be applied to the concrete floor surface prior to installation of the new flooring material to achieve a finished floor with a field impact isolation classification in excess of FIIC 55. Failure to do this will result in the transference of impact noise to the apartment below.
A lessee or occupier of a lot must not, without the prior approval in writing of the body corporate committee and subject to any conditions the committee may impose:-
a) remove or install any hard floor surfaces unless it achieves a minimum field impact isolation control of 55 under relevant Building Code Regulations and is suitably acoustically treated; or
b) interfere with any ceiling acoustic treatment.
Alpha Acoustics holds the stance that [the requirements of the NCC] is only a minimum floor impact noise criterion that must be met and it is not an appropriate criterion for an apartment block where a higher standard of acoustic privacy may be expected especially considering a case where an apartment was built and sold with carpeted floors which achieve a much higher floor impact noise rating. In the case of a floor that was originally designed for a carpeted covering, it may be argued that the floor/building was designed with the carpet floor impact noise performance and hence it may become a legal matter as to whether simply meeting the NCC minimum requirements is adequate.
But the question is asked "what level of floor impact noise interferes with the peaceful enjoyment of a person especially given humans react differently to noise emissions. Therefore, although this law has the intent to protect occupiers and tenants of other lots from noise impacts, at times legal disputes occur because there may be differing interpretations of this law.
Therefore, to avoid legal disputes, it is possible for a Body Corporate to specify an exact noise impact criterion to ensure an agreed standard of acoustic privacy is maintained. This specification can be tested if a dispute arises or if a timber/tile flooring system has an unknown acoustic performance.[13]
If a tenant has grown accustomed to a high standard of acoustic privacy then that tenant may be sensitive to a degrading of the acoustic ambience even if the new acoustic privacy is perhaps an average to good performance (perhaps 3 to 4 Star rating).[14]
a) the current by-laws which do not operate to place a blanket prohibition on hard-flooring installations; > > b) experts who have determined the prescribed impact noise performance is difficult to achieve, but not impossible with hard floor coverings; > > c) the original construction of the building(s) being designed with a high floor impact noise criterion (i.e. carpet being installed); and > > d) the quality of the development being high range given its location.
Finally, I do not consider that the by-law is unreasonable simply because the advice obtained by the body corporate, in the light of which it imposed the 45dB requirement, noted that it would be extremely difficult for hard flooring to comply. The evidence before the adjudicator indicated that, although difficult, it was possible to comply using hard flooring. As I have said above, in the light of the inadequacy of the evidence about the effects on the apartment of flooring about 42 to 51mm thick, combined with evidence that other lot owners had installed hard flooring with the body corporate's consent, the evidence did not go so far as to prove that it was practically so difficult as
to be impossible to comply with the by-law.[18]
[1] Section 88(1) of Schedule 4 of the SBCA
20Insulation%20in%20Buildings%20handbook%202022.pdf
[4] See Palmer Acoustics Report for Unit 2218 of 4 November 2020
[5] See Redman v The Proprietors - Fairway Island GTP 107328 [2020] QDC 68 @ [32] to [33], noting that the Plan formed part of a residential precinct within Hope Island Resort, created under the Integrated Resort Development Act 1987.
[6] See Gracemere Waters North [2011] QBCCMCmr 389, at [31], citing Commonwealth v Tasmania [1983] HCA 21; (1983) 46 ALR 625; Minister for Resources v Dover Fisheries Pty Ltd [1993] FCA 366; (1993) 116 ALR 54.
[7] Marina Residences [2020] QBCCMCmr 648 @ [16], citing Redman v The Proprietors - Fairway Island GTP 107328 [2020] QDC 68 at [31] and following
[8] See for example, Pandanus Mooloolaba [2017] QBCCMCmr 78; Liberty [2015] QBCCMCmr 371
[10] [2015] QBCCMCmr 11 @ [25]
[11] Marina Residences [2020] QBCCMCmr 648 @ [19]
[12] [2020] QDC 68 at [69]- [70]
[13] Proposed Floor Impact Noise Insulation Criteria Report, Alpha Acoustics Pty Ltd dated 15 April 2019 (Alpha Acoustics Report), at para 3.2.
[15] See the statement from the body corporate's chairperson in Annexure E of the committee's submission.
[16] Williamson v Princess Palm Body Corporate CTS 9843 [2010] QCATA 55
[19] Body Corporate for River City Apartments v McGarvey [2012] QCATA 47
[20] Admiralty Towers II [2021] QBCCMCmr 519
(1993) 116 ALR 54
(1983) 46 ALR 625