[2020] QIRC 235
General information, not legal advice.
Queensland Industrial Relations Commission
2020-12-24
O'Connor VP, Ms P, Mr P
Original judgment source is linked above.
WORK HEALTH AND SAFETY - EXTERNAL REVIEW - INTERLOCUTORY APPLICATION - APPLICATION FOR STAY OF OPERATION OF DECISION AND IMPROVEMENT NOTICE - whether jurisdiction to order stay pursuant to s 229C of the Work Health and Safety Act 2011 - whether stay should be ordered - whether the applicant has an arguable case - whether the balance of convenience and competing rights of the parties is in favour of the application - whether there is a risk of the review being abortive without the stay.
Work Health and Safety Regulation 2011 (Qld), r 315K
Alexander v Cambridge Credit Corporation Ltd (1985) 2 NSWLR 685
Ninemia Maritime Corp v Trave GmbH & Co KG "The Niedersachsen") [1984] 1 All ER 398
Patterson v BTR Engineering (Aust) Ltd (1989) 18 NSWLR 319
Frigo v Culhaci [1998] NSWCA 88
Multiplex Constructions Pty Ltd v the Regulator under the Work Health and Safety Act 2011 [2018] QIRC 116
Queensland Bacon Pty Ltd v Rees [1966] HCA 21; (1966) 115 CLR 266
Commissioner of Corporate Affairs v Guardian Investments Pty Ltd [1984] VicRp 81; [1984] VR 1019
Ms P. Bindon, Counsel instructed by Mr R. Abdel-Massih for the Applicant.
Mr P. Waltham, and with him Ms C‑L. Godfrey, for the Respondent.
I, David Cappelletti reasonably believe on 29-SEP-2020 at 15:30 that you are contravening a provision of the: Work Health and Safety Regulation 2011 - regulation 315K(2).
I carried out an inspection on site and observed a large Gantry which has been erected around parts of the construction site over the public footpath areas. The gantry is carrying various site sheds such as offices, toilets and lunch rooms. The gantry support posts are close to a very busy road system which carries trucks, cars, motor bikes etc. These posts have not been guarded or protected against the risk of impact from passing vehicles, which may lead to failure or collapse of the gantry system.
(a) be able to stop an object that may reasonably be expected to fall on it from falling; and
(b) have an overhead platform that is secured to prevent it lifting or coming apart; and
(c) have solid sheeting erected along the outer edge of its overhead platform to at least the higher of -
(ii) the height of any object stored on the platform; and
(d) if it is used to store materials or has a shed erected on it - be designed by an engineer to take the additional load involved; and
(e) be able to stop water or dust falling on persons; and
(f) have natural or other lighting of at least 50 lux illuminating all of the area below it; and
(g) not tip over or rotate if a force that could reasonably be expected to be applied to it is applied to it.
Example of a force mentioned in paragraph (g) - the force of a truck backing into the gantry.
(a) be able to stop an object that may reasonably be expected to fall on it from falling; and
(b) have an overhead platform that is secured to prevent it lifting or coming apart; and
(c) have solid sheeting erected along the outer edge of its overhead platform to at least the higher of -
(ii) the height of any object stored on the platform; and
(d) if it is used to store materials or has a shed erected on it - be designed by an engineer to take the additional load involved; and
(e) be able to stop water or dust falling on persons; and
(f) have natural or other lighting of at least 50 lux illuminating all of the area below it; and
(g) not tip over or rotate if a force that could reasonably be expected to be applied to it is applied to it.
(a) there was no proper basis for the inspector to have formed the reasonable belief asserted in the Improvement Notice;
(b) the directions the inspector made in the Improvement Notice for measures required to be taken to remedy the contravention were incapable of being complied with because they merely repeated regulation 315K(2); and
(c) the issue of the Improvement Notice was inconsistent with the National Compliance and Enforcement Policy.
(1) An eligible person may apply to the external review body for a review (an external review) of -
(a) a reviewable decision made by the regulator; or
(b) a decision made, or taken to have been made, on an internal review.
(2) A review by QCAT is provided for under the QCAT Act.
See QCAT Act, chapter 2, part 1, division 3 (Review jurisdiction).
(3) A review by the commission is provided for under division 4.
(1) The commission may grant a stay of the decision to secure the effectiveness of the review.
(a) may be given on the conditions the commission considers appropriate; and
(b) operates for the period fixed by the commission; and
(3) The period of a stay must not extend past the time when the commission decides the application.
(4) An application affects the decision, or carrying out of the decision, only if the decision is stayed.
1. The onus is upon the applicant to demonstrate a proper basis for a stay which will be fair to all parties.
2. The mere filing of an appeal does not demonstrate an appropriate case or discharge the onus.
3. The court has a discretion involving the weighing of considerations such as balance of convenience and the competing rights of the parties.
4. Where there is a risk that the appeal will prove abortive if the appellant succeeds and a stay is not granted, courts will normally exercise their discretion in favour of granting a stay.
5. The court will not generally speculate upon the appellant's prospect of success but may make some preliminary assessment about whether the appellant has an arguable case, in order to exclude an appeal lodged without any real prospect of success simply to gain time.
(a) there was no proper basis for the inspector to have formed the reasonable belief asserted in the Improvement Notice;
(b) the directions the inspector made in the Improvement Notice for measures required to be taken to remedy the contravention were incapable of being complied with because they merely repeated regulation 315K(2); and
(c) the issue of the Improvement Notice was inconsistent with the National Compliance and Enforcement Policy.
Contact gantry installer and carry out traffic monitor for possibility of providing protection to gantry posts from vehicle impact.
I've had a look at the attached engineer's certification letter. He has been careful in his comments about vehicle impact loadings - which you would expect to be the case. To me he is trying to say that if a vehicle hits one post the remaining three posts should prevent total failure of the gantry. But if a vehicle hits one leg and buckles then the whole structure will be affected - for example a corner will be pulled down and the whole deck will tilt. If the there (sic) are site sheds on top then the site shed will also tilt and there is a risk of the site shed dislodging or the whole structure becoming unstable.
To my knowledge, the standard industry practice is to place concrete collision barriers between the posts of gantries. These have the two advantages of providing more mass to absorb the impact of a vehicle collision and of redirecting a vehicle's path so that it is less likely to collide with a post on the gantry. With this in mind I think there is a good argument for making the PCBU install concrete barriers - especially if the gantry is next to a busy road.
Looks like they might be putting the ball back into your court for doing a risk assessment and implement the necessary controls if required. As I don't know the traffic flow, types of vehicles, road layout etc it will be up to you to look at all these parameters and implement controls accordingly.
I have a couple of audits done recently by Aaction Traffic, which highlights the amount of traffic. Generally the busy times vary however will carry out a risk assessment and monitor for the future....
The Guardian Gantry System is a modular system comprising of standard units - decks, posts, adjustable feet, concrete ballast infills and handrails that are connected together to form a structure which can sustain vertical loading up to 10kPa (1000kg per square metre) and relevant wind loads appropriate to the construction location.
While vehicular impact loadings have not been specifically catered for in the design process, the nature of the design by provision of redundant legs and bolted connections between adjacent modules is such that a vehicular impact and subsequent failure of a single post will not result in the failure of the entire structure. Increased deflections should be expected as a result of post failure.
If the location where the gantry is erected is abnormal or unusual then it is recommended that the hirer/end user do their own risk management assessment and provide protection to the posts accordingly.
The objective circumstances sufficient to show a reason to believe something need to point more clearly to the subject matter of the belief, but that is not to say that the objective circumstances must establish on the balance of probabilities that the subject matter in fact occurred or exists: the assent of belief is given on more slender evidence than proof. Belief is an inclination of the mind towards assenting to, rather than rejecting, a proposition and the grounds which can reasonably induce that inclination of the mind may, depending on the circumstances, leave something to surmise or conjecture.
A suspicion that something exists is more than a mere idle wondering whether it exists or not; it is a positive feeling of actual apprehension or mistrust, amounting to a 'slight opinion, but without sufficient evidence', as Chamber's Dictionary expresses it. Consequently, a reason to suspect that a fact exists is more than a reason to consider or look into the possibility of its existence. The notion which 'reason to suspect' expresses in sub.s.(4) is, I think, of something which in all the circumstances would create in the mind of a reasonable person in the position of the payee an actual apprehension or fear (that the situation of the payer is in actual fact that which the sub-section describes - a mistrust of the payer's ability to pay his debts as they become due and of the effect which acceptance of the payment would have as between the payee and other creditors.
a. it is overbroad, and therefore both unreasonable and uncertain; and
b. it lacks particularity in that there is no indication of how the general terms of reg 315K(2) (or any part of it) are to be addressed by the Applicant in its particular circumstances.
(g) not tip over or rotate if a force that could reasonably be expected to be applied to it is applied to it.
Example of a force mentioned in paragraph (g) - the force of a truck backing into the gantry.
then the Applicant will suffer the difficulties namely it will be required to dismantle the entire gantry and remove the site sheds which the gantry currently houses, at considerable cost and delay to the critical path of the Applicant's construction project at the Site.
[1] Person conducting a business or undertaking.
[3] Ninemia Maritime Corp v Trave GmbH & Co KG ("The Niedersachsen") [1984] 1 All ER 398, 404.
[4] See: Patterson v BTR Engineering (Aust) Ltd (1989) 18 NSWLR 319 at 325 per Gleeson CJ; Frigo v Culhaci [1998] NSWCA 88.
[5] Affidavit of David Cappelletti affirmed 11 December 2020, Exhibit DC1
[7] Affidavit of Michael Cunningham sworn 18 December 2020, [28]-[30].
[9] (1990) CLR 104, [14].
[12] See: s 3 Work Health and Safety Act 2011.
[13] Multiplex Constructions Pty Ltd v the Regulator under the Work Health and Safety Act 2011 [2018] QIRC 116.
[14] Affidavit of Michael Cunningham sworn 18 December 2020, [43]; Exhibit MC15.
MPG Constructions Brisbane Pty Ltd
The Regulator under the Work Health and Safety Act 2011 [2020] QIRC 235
(1985) 2 NSWLR 685
(1989) 18 NSWLR 319
(1966) 115 CLR 266