[2014] VCAT 1291
General information, not legal advice.
Victorian Civil and Administrative Tribunal
2014-10-17
Mr J
Original judgment source is linked above.
$51,773.76 in accordance with the report of Mr Ryan,
$300 for the AAMI excess for the household insurance claim of 2010,
$2,547.40 for temporary repairs [by] Vic Constructions Pty Ltd, and
$866 being the cost claimed for rectification of drainage to the south side of the dwelling, leading from the portico.
There was no evidence to suggest that the existing conditions of the steps and the landings are causing water ingress or deterioration of the internal building elements.
There is a gap between the timber landing and the timber door sill that will allow the door sill to drain under the landing, which has been constructed over brickwork; and there is no evidence to suggest that there is structural or foundation movement in the steps or landing.
My re-inspection revealed that there is a concrete structure under the tiled timber steps and landing. I observed that on each side of the porch, there is a gap from the concrete to the outside edge of the porch tiles of approximately 80 mm to 90 mm which is unsupported except for the rotting timber cladding.
The unsupported porch tiles have the potential to crack due to not being fully supported as required. NB: Potential for safety hazard if tiles break.
... the stone door sill has always been lower than the timber porch landing and had the potential for water to enter the dwelling prior to the aluminium door screen track being installed by the Owner.
... there has been some deterioration of the door jamb, which appears to be related to the blockage of the door sill by the fitting of a sliding screen across the door opening, which is preventing the full drainage of the door sill.
There was no evidence of water ingress around or through the doors or windows, except for the door opening on to the landing and stairs, that has deteriorated at the top of the door jamb, possibly due to a metal sliding door guide that appears to be causing water retention above the door and premature deterioration of the timber.
In my professional opinion, the cause of mould to the door and window frame is caused by the window and door frame being proud of the wall and not being sealed properly to the solid brick wall[4]. This is therefore allowing rain water ingress into the frames from where this water/moisture is causing the damage.
... the main cause of the water damage and deterioration to the top of the door opening on to the landing and stairs is related to works undertaken by the existing owners with the fitting of a metal guide that would restrict discharge of water from the top of the door.
... the previous balcony floor level was higher than the bedroom external door sill. This has resulted in the timber door frame rotting.
I am not satisfied that Mr Ryan saw the balcony in this condition, therefore I am not confident that he can accurately report its previous state. However, I accept his evidence that the door sill and frame are damaged from rot.
The newly tiled balcony appears to be lower than the original balcony floor level.
Mr Ryan has drawn this conclusion by observing that there is approximately 35 mm of grout between the top of the tiled surface and the bottom of the existing timber skirting installed on the rendered balustrade. Mr Ryan has not described how the new tiled floor could be lower than the old, without substantial reconstruction of the substrate to the floor. I am not satisfied that the only explanation for the height of the grout is the height of the pre-existing floor.
Mr Ryan has based his conclusion that the owner-builder is responsible for rotting to the door frame and sill on his view that there should have been a step down to the tiled balcony of between 50 mm and 100 mm. While I agree that a step is necessary, the Owners have had the balcony floor finished at a level which is too high and have either caused or exacerbated the lack of drainage from the sill.
I have been advised that the original balcony was constructed of timber decking over an aluminium alloy metal deck roof and that the new owners have replaced this with tiling at the same level as the internal finished floor level, which is therefore considered to be a breach of Australian Standard 4654.2 - 2009 regarding Waterproofing Membranes to External Aboveground Areas.
... it was brought to my attention that the present owner had undertaken major structural works to the balcony area, and any damage to the balustrade capping could have occurred during these works.
...the [owner-builder] has installed slate floor tiling without an appropriate overhanging and drip. As a result, a crack has developed in the grouting which is allowing moisture to be drawn back in between the grouting and the timber framing.
AAMI excess for the household insurance claim of 2010 - $300
Job: As quoted by email 20-4-10. Supply and install Liquid Rubber Membrane system to upper level deck area.
Temporary repairs by Vic Constructions Pty Ltd - $2,547.40
Rectification of drainage to the south side of the dwelling, leading from the portico - $866
Down-pipes Not connected to the storm water system. Minor defect Type F
Water ponding close to footings will cause subsidence over time. Connection to the stormwater system should be carried out immediately.
The accompanying photograph is of the bottom of the down pipe claimed in this item, but I note that the report concerns "down-pipes" expressed as plural, not singular.
Temporary repairs by Vic Constructions Pty Ltd $2,547.40
[1] Mrs Pollara claimed that as the value of the works undertaken by her was less than $12,000, no warranty insurance was necessary. The Owners claimed the true value of the works was significantly greater, but as no monetary or other claim turns on this issue, it is unnecessary to consider further.
[2] This appears to be the same item as in paragraph 29b above.
[3] as discussed below, this filling was installed by Mr Mahfouz.
[4] This wall is not solid brick, but light weight cladding. Nevertheless, I am satisfied that Mr McCann has correctly identified the position of the door frame as being defective.
Mohamed