CONTRACTS - BUILDING, ENGINEERING AND RELATED CONTRACTS - PERFORMANCE OF WORK - REMEDIES FOR BREACH OF CONTRACT - DAMAGES - MEASURE OF - where no enforceable contract - where finding of negligent construction work open on the application and statements of evidence - where damages for negligent construction work awarded
Civil Liability Act 2003 (Qld), s 9, s 11
Queensland Building and Construction Commission Act 1991 (Qld), s 13(2), s 13(5), s 44, s 77(1), Schedule 1B
Belgrove v Eldridge [1954] HCA 36; (1954) 90 CLR 613
Caltex Refineries (Qld) Pty Ltd v Stavar [2009] NSWCA 258
Drexel London (a firm) v Gove (Blackman) [2009] WASCA 181
March v E & MH Stramare Pty Ltd [1991] HCA 12; (1991) 171 CLR 506
Thompson and Anor v Jedanhay Pty Ltd [2012] QCATA 246
(a) on 12 March 2017 a quotation dated 11 March 2017 was emailed to them by Mr van Uden;
(b) on a date and time unknown, but before 9.26 am on 13 March 2017 the quotation was accepted; and
(c) on 13 March 2017 at 9.26 am Mr van Uden emailed the Atkinsons stating: 'Thank you for accepting quote. I can start beginning next week if you like...'
Shower cabin, cabinet, tiling, waterproofing will be installed by 'The Flying Dutchman'
Painting is Not included
Installing tiles, tile glue, grouting, finished will be performed by 'The Flying Dutchman'
All taps, shower heads etc will be re-installed when tile job is done.
Shower base, vanity and toilet done by Terrance.
All Electrician, Plumbing and Painting arranged and performed by Terry
This include: Connecting/installing shower base, vanity, toilet in ensuite, taps, plumbing, waterwaste underneath house.
(b) Structural floor joist compromised as a result of the pre-formed shower base installation in the main bathroom. The floor joist has been completely cut to allow installation of the waste pipe. The bathroom floor has inadequate support.
(c) Wall tiles may not have been installed correctly over the pre-formed shower base upstand/lip. Invasive investigation could confirm the as-constructed detail.
(d) Water leaks from around the shower waste and from underneath the shower base. Failure has occurred in several locations, including the junction of the shower wall and floor. Visual inspection noted water staining evident to the plywood flooring at the bathroom vanity drainage pipe indicating a failure of the waterproofing membrane to the bathroom floor.
(e) The extent of staining indicates water is leaking from within the shower enclosure and underneath the bathroom floor tiles.
(f) Water leakage evident from the base of the shower screen.
(a) there is a dispute as to whether existing damaged particleboard floor sheeting would be replaced in the ensuite. The particleboard has not been replaced. Damaged flooring requires replacement.
(b) Efflorescence and discoloured grout is evident on the floor tiles throughout the room indicating the adhesive/bedding underneath the floor tiles is waterlogged.
(c) Visual inspection noted an inadequate and defective waterproofing detail at the ensuite bathroom doorway, in that the waterstop angle has not been finished flush with the tiled floor surface.
(d) A non-invasive water test revealed moisture in several locations of the tile grout on the ensuite floor, water leakage evident in the subfloor area under the ensuite, water leaking from two separate locations of the flooring, not in the vicinity of the shower waste.
(e) Water testing indicates that the junction of the shower wall tiles and shower base is defective, allowing water leakage.
(f) Water is escaping the shower cubicle (under tiles and/or shower tray) and tracking under the bathroom floor tiles.
(g) The waterproofing membrane to the ensuite floor is defective and has failed with visible leakage underneath the flooring in two separate locations.
(h) Water leakage is evident from the base of the shower screen as a result of a static water test.
(a) The installation of the pre-formed shower base, wall lining, waterproofing membrane, wall and floor tiles and shower screen to the main bathroom is not in accordance with the Building Code of Australia, AS3740-2010, or acceptable building practice in that floor framing has been compromised and water leakage occurs causing damage to various building elements.
(b) The installation of the preformed shower base, wall lining, waterproofing membrane, wall and floor tiles and shower screen to the ensuite bathroom is not in accordance with the Building Code of Australia, AS 3740-2010, or acceptable building practice, allowing water leakage and causing damage to various building elements.
(a) a duty of care owed by Mr van Uden to the Atkinsons;
(b) that the duty of care was breached;[5]
(c) damage which is not too remote has been suffered by the Atkinsons as a consequence;[6] and
[1] Statement of Marcio Mendonca dated 22 November 2019 - Exhibit 4.
[2] Attachment 1 to the statement of Mr and Mrs Atkinson filed 12 September 2019 - Exhibit 3.
[3] Attachment 3 to the statement of Mr and Mrs Atkinson filed 12 September 2019 - Exhibit 3.
[4] Thompson and Anor v Jedanhay Pty Ltd [2012] QCATA 246, [22]: the Tribunal generally derives the issues to be determined from the statements of evidence of the parties.
[5] Civil Liability Act 2003 (Qld), s 9, Schedule 2 (definitions of 'duty' and 'duty of care'): "duty" means a duty of care in tort; "duty of care" means a duty to take reasonable care or to exercise reasonable skill (or both duties).
[6] Civil Liability Act 2003 (Qld), s 11.
[7] Bryan v Maloney (1995) 182 CLR 609, paras 6, 14, 18 and 19 per Mason CJ, Deane and Gaudron JJ; Caltex Refineries (Qld) Pty Ltd v Stavar [2009] NSWCA 258, [102]-[103].
[8] Drexel London (a firm) v Gove (Blackman) [2009] WASCA 181, [214]: breach of a statutory duty such as failing to follow a building code, while not determinative is strong evidence of negligence.
[9] Civil Liability Act 2003 (Qld), s 11(1)(a).
[10] March v E & MH Stramare Pty Ltd [1991] HCA 12; (1991) 171 CLR 506, 515.
[11] Civil Liability Act 2003 (Qld), s 11(1)(b) and (4).
[12] Damien Cremean, Michael Whitten and Michael Sharkey_, Brooking on Building Contracts_ (Lexis Nexis Butterworths, 6th ed, 2020) 16.9.
[13] Belgrove v Eldridge [1954] HCA 36; (1954) 90 CLR 613.
Atkinson & Anor
Van Uden [2020] QCAT 259