#### sch.2-sec-oc.7 Solid fuel heaters (including oil-fired appliances)
Solid fuel heaters (including oil-fired appliances)
> > (1) Must be tested to comply with AS/NZS 4012:2014, Domestic solid fuel burning appliances—Method for determination of power output and efficiency and AS/NZS 4013:2014, Domestic solid fuel burning appliances—Method for determination of flue gas emission.
>
> > (2) Must be installed in accordance with AS/NZS 2918:2018, Domestic solid fuel burning appliances—Installation.
>
> > (3) If a boiler or pressure vessel—must be installed in accordance with AS/NZS 1200:2015, Pressure equipment.
>
> > (4) Flues and chimneys must not terminate in such a position as to constitute—
> >
> > > (a) a risk of fire to nearby combustibles, or
> >
> > > (b) a risk of penetration of the flue gases through nearby windows or other openings, fresh air inlets, mechanical ventilation inlets or exhausts, or the like.
>
> > (5) Flue and chimney heights must be at least 1.0m above the height of any structure or topographical feature within a 15m radius of the chimney with a maximum chimney height of 2m above the ridge of the roof on which it is installed.