QLDIn ForceRegulation
Coal Mining Safety and Health Regulation 2017
sec.247Other explosion-protected electrical plant
Start here
Get a plain-English read of sec.247
Turn the raw legal text into a practical explanation grounded in Coal Mining Safety and Health Regulation 2017.
### sec.247 Other explosion-protected electrical plant
This section applies to explosion-protected electrical plant supplied with electricity by a trailing cable, other than plant—
mentioned in sections 245 and 246 ; or
fitted with an automatic methane detector; or
having explosion protection category Ex ia.
If a general body concentration of methane of at least 1.25% is detected around the plant, the person detecting the methane must immediately switch off the electricity supply to the equipment’s trailing cable.
(sec.247-ssec.1) This section applies to explosion-protected electrical plant supplied with electricity by a trailing cable, other than plant— mentioned in sections 245 and 246 ; or fitted with an automatic methane detector; or having explosion protection category Ex ia.
(sec.247-ssec.2) If a general body concentration of methane of at least 1.25% is detected around the plant, the person detecting the methane must immediately switch off the electricity supply to the equipment’s trailing cable.
- (a) mentioned in sections 245 and 246 ; or
- (b) fitted with an automatic methane detector; or
- (c) having explosion protection category Ex ia.