{"id":"F2006B09448","name":"AD/ELECT/73 - Britax Sell Galley Equipment","slug":"ad-elect-73-britax-sell-galley-equipment","collection":"legislative_instrument","jurisdiction":"commonwealth","status":"in_force","isInForce":true,"actNumber":null,"makingDate":null,"administeringDepartment":null,"currentVersion":{"id":53886,"registerId":"commonwealth-F2006B09448-current","compilationNumber":null,"startDate":"2026-04-02","status":"InForce","reasons":null,"registeredAt":null},"sections":[{"sectionNumber":"AIRWORTHINESS DIRECTIVE","sectionType":"part","heading":"AIRWORTHINESS DIRECTIVE","content":"# AIRWORTHINESS DIRECTIVE\n\n![](image.002.png)\n\n![](image.002.png)  \nFor the reasons set out in the background section, the CASA delegate whose signature appears below issues the following Airworthiness Directive (AD) under subregulation 39.1 (1) of CAR 1998. The AD requires that the action set out in the requirement section (being action that the delegate considers necessary to correct the unsafe condition) be taken in relation to the aircraft or aeronautical product mentioned in the applicability section: (a) in the circumstances mentioned in the requirement section; and (b) in accordance with the instructions set out in the requirement section; and (c) at the time mentioned in the compliance section.","sortOrder":0},{"sectionNumber":"AD/ELECT/73 Britax Sell Galley Equipment","sectionType":"part","heading":"AD/ELECT/73 Britax Sell Galley Equipment 1/2001","content":"# AD/ELECT/73 Britax Sell Galley Equipment 1/2001\n\nApplicability: Galley equipment manufactured by Britax Sell GmbH & Co OHG, Herborn, Germany with Part Numbers (P/N) as listed below equipped with a Tank Assembly P/N 62203-001-005, 62197-015-001, 64761-025-001, 64769-025-003, 64771-025-\n\n005, 64771-025-001 or 64790-331-001.\n\nNote 1: Affected Serial Numbers are listed in the applicable Britax Sell GmbH & Co OHG Service Bulletins (SB) referenced below.\n\nEquipment Part Number\n\nRemote Water Boiler 62204-001-029, 62204-001-031, 62204-001-037\n\n62204-001-043, 62204-001-047 and 62204-001-049\n\nCoffee Maker 64755, 64753-001-003, 64763-201-003, 64769-001-005,\n\n64769-001-007 and 64790-1\n\nWater Boiler 62197-001-001\n\nBeverage Maker 64771 001-001 and 64771-001-003\n\nRequirement: 1. Inspect the Faston Terminal P/N 3-520133-2 (with blue Nylon insulation) connected to the contact pins of Thermal Limiters P/N AC 1544 or P/N AC 1693, as applicable, for electrical arcing, discoloration or signs of over heating such as insulation melting.\n\n    2. If any damage is detected during the Requirement 1 inspection replace the affected wires in accordance with the applicable SB as follows:\n\n| Service Bulletin Number                      | Equipment Part Number        |\n| -------------------------------------------- | ---------------------------- |\n| E33-4-007SB Revision 1 dated 30 October 2000 | 62204-001-029, 62204-001-031 |\n|                                              | 62204-001-037, 62204-001-043 |\n|                                              | 62204-001-047, 62204-001-049 |\n| E33-4-009SB dated 24 October 2000            | 64755                        |\n| E33-4-010SB dated 20 October 2000            | 62197-001-001                |","sortOrder":1}],"analysis":{"flash_summary_failed":{"failed":true,"reason":"Unauthenticated. Configure AI_GATEWAY_API_KEY or use a provider module. Learn more: https://ai-sdk.dev/unauthenticated-ai-gateway","source":"analysis-cron"},"flash_summary":{"complexity_score":4,"scope_assessment":{"changed":false,"description":"The AD limits action to inspection and replacement of wiring on specified Britax Sell galley equipment P/Ns and serial numbers per the referenced service bulletins. Nothing in the text indicates an expansion or narrowing of that applicability beyond the listed parts and the SB cross-references (Applicability; Requirement 1–2; Note 1)."},"complexity_factors":["Detailed lists of affected equipment by Part Number and referenced Tank Assembly P/Ns create precision but require cross-checking (Applicability).","Affected serial numbers are held in multiple Britax Sell service bulletins, requiring retrieval and verification against operator inventories (Note 1).","Compliance requires a qualified inspection for electrical arcing/overheating signs, which involves subjective assessment and technical judgement (Requirement 1).","Corrective action mandates replacement per specific service bulletins, so maintainers must follow multiple SBs with differing dates and revisions (Requirement 2 and SB table).","The AD refers to timing in a compliance section not reproduced here, which can create uncertainty about required deadlines if not consulted (preamble)."],"plain_english_summary":"This Airworthiness Directive requires inspection of a specific Faston terminal (P/N 3-520133-2) on listed Britax Sell galley units for electrical arcing, discoloration or melted insulation, and replacement of affected wiring in accordance with the manufacturer’s service bulletins. It applies to operators and maintenance organisations using the listed galley part numbers and serial numbers. Operators must arrange and pay for the inspection and any corrective work, and must carry out actions as set out in the AD and the referenced service bulletins (Applicability; Requirement 1–2)."},"kimi_summary":{"content_quality":"rejected","complexity_score":3,"rejection_reason":"The document is clearly incomplete — it cuts off mid-table in the Requirement section, the Compliance section (which specifies deadlines for action) is entirely missing, and the document appears to be a fragment or stub rather than the complete legislative instrument.","scope_assessment":{"changed":false,"description":"This appears to be a standard, targeted airworthiness directive addressing a specific safety defect in specific aircraft equipment. There is no indication of scope creep; it maintains the typical narrow focus of ADs on particular unsafe conditions in defined aeronautical products."},"complexity_factors":["Highly specific technical scope: applies only to specific part numbers from a single manufacturer","Multiple cross-references to external manufacturer service bulletins (SBs) for repair procedures","Conditional logic: inspection required, but replacement only 'if damage is detected'","Truncated content: the document appears incomplete (ends mid-table, compliance section missing)","Dense part numbering system requiring precise identification of affected equipment"],"plain_english_summary":"This CASA Airworthiness Directive legally requires operators of aircraft fitted with certain Britax Sell galley appliances to inspect and, where necessary, repair or replace wiring on affected tank/thermal-limiter assemblies. It responds to electrical arcing/overheating that can melt insulation and start galley fires. Compliance is mandatory to remove the in‑flight fire risk and keep affected aircraft releaseable."}},"importantCases":[],"_links":{"self":"/api/acts/ad-elect-73-britax-sell-galley-equipment","history":"/api/acts/ad-elect-73-britax-sell-galley-equipment/history","analysis":"/api/acts/ad-elect-73-britax-sell-galley-equipment/analysis","conflicts":"/api/acts/ad-elect-73-britax-sell-galley-equipment/conflicts","importantCases":"/api/acts/ad-elect-73-britax-sell-galley-equipment/important-cases","documents":"/api/acts/ad-elect-73-britax-sell-galley-equipment/documents"}}